Lieferzeit in ganz Litauen: 5-10 Werktage
Lieferpreis an die angegebene Adresse: 3 Euro
Trumpai apie prekę
Prekė: pH matuoklis akvariumui ir baseinui su temperatūros funkcija. Kategorija: Filtravimo ąsočiai ir buteliai.
- Gamintojas: Tessa
- Modelis: other (pH-2 Pro (2))
- pH measurement range: 0,0 - 14,0 pH
- Measurement resolution: 0,01 pH
- Accuracy: ± 0,01 pH (with calibration up to 4,01 pH; 6,86 pH; 9,18 pH)
- Accuracy: ± 0,1 pH (only up to 6,86 pH when calibrated)
- Backlit LCD
- LCD color change depending on pH value (litmus strips)
- Operating temperature: 0 - 60 °C
- Relative humidity: < 95 %
- Liquid Temperature Compensation (ATC)
- Calibration: factory, electronic, two-point/three-point
- Brand new, calibrated product
- All meters are ready for use, checked and calibrated to 3 points (4,01 pH; 6,86 pH; 9,18 pH)
- Dimensions: 155mm X 32mm X 18mm
- Weight: 50g (100g with accessories)
- Power supply: 2 x 1,5V LR44 battery (included)
- Battery life: about 500 hours of use (Automatic shutdown)
- Additional buffers (4,01 pH; 6,86 pH; 9,18 pH) available at our other auctions
- Electronic pH tester with backlight and ATC function
- Protective cap
- Buffer for calibration 4.01, 6.86 and 9,18 pH (for reconstitution with known pH)
- Plastic box/case
- Detailed instruction in English
- Detailed instruction in Polish can be downloaded from the "Additional information" tab located at the bottom of the page.
- Battery compartment
- LCD display
- On button
- Calibration/mode change button
- Measuring electrode
- Protective cap
- aquaristics
- gastronomy
- agriculture, forestry, water protection
- gardening, hydroponics
- Pools & Spas
- food industry
- chemical industry
- distilling and brewing
- ph determination of water, urine, sewage, etc.
- wherever pH measurement of the liquid is needed
ATC function (Automatic Temperature Compensation) - temperature measurement and compensation indication of the tester in the range of 0-50°C. Thanks to this, we obtain an accurate result of acidity of a given liquid.
Due to the pH variability of the liquid relative to its temperature, only an acid meter with the ATC function allows to obtain a reliable result consistent with the actual average value.
The pH tester complies with EU directives and is marked with the CE mark. In addition, the pH tester is made of materials that meet the strict requirements of the EU ROHS directive.
Do not touch the sensor electrode, the oil on the skin can damage the sensor and affect the readings.
- Make 3 solutions (4,01 pH; 6,86 pH, 9,18 pH) with known pH using 250 ml of distilled water each and calibration buffers.
- Dip the tester electrode into a solution with pH 6,86 (at 25 ℃), gently stir and wait for the reading to stabilize (no changes for 5 seconds).
- Press the "CAL" button (calibration) for 5 seconds and release. Wait for the display to show 6,86 pH and stop flashing.
- Clean the electrode in distilled water and dry (e.g. using a paper towel), then immerse the electrode in a solution with pH 4,01 (at 25 ℃), gently stir and wait for the reading to stabilize (no changes for 5 seconds).
- Press the "CAL" button for 5 seconds and release. Wait for the display to show 4.01 pH and stop flashing.
- Clean the electrode in distilled water and dry (e.g. using a paper towel), then immerse the electrode in a solution with pH 9,18 (at 25 ℃), gently stir and wait for the reading to stabilize (no changes for 5 seconds).
- Press the "CAL" button for 5 seconds and release. Wait for the display to show 9.18 pH and stop flashing.
- Clean the electrode in distilled water and dry (e.g. using a paper towel), then place the meter back in the buffer solution to test the calibration. If it is incorrect, repeat the calibration.
- Remove the protective cap. If crystals appear under it, this is not a cause for concern, this is normal with pH tester electrodes. The problem will disappear after rinsing the electrode with cleaning liquid/water.
- Turn on the tester with the "ON/OFF" button and immerse the pH meter electrode in the test liquid. Gently mix until the displayed value stabilizes, then read the value from the display.
- After the measurement, rinse the electrode with water and wipe with a cloth. Put on a protective cap
NOTE!
If the readings of the same liquid differ from each other, recalibrate the meter using the buffers included in the kit.
- Clean the electrode with distilled water each time before and after use
- Do not touch the sensor electrode, as the oil on the skin can damage the sensor and affect the readings.
- Do not immerse the meter in the solution above the immersion line to avoid damaging the circuits.
- After replacing the battery or opening the battery compartment, recalibration is necessary.
- Store the meter with a few drops of electrode storage fluid in the protective cap (e.g. GIB KCL or Growth Technology). Lack of this action may affect the correctness of readings and the life of the device.
- Large differences in readings can be due to the need for calibration, a dry electrode or weak batteries.
Specifications
| Group | Name | Value |
|---|---|---|
| Parametry | Condition | new |
| Parametry | Invoice | With VAT invoice |
| Parametry | Brand | Tessa |
| Parametry | Model | other (pH-2 Pro (2)) |
| Parametry | Manufacturer code | pH-2 Pro (2) |
| Parametry | EAN (GTIN) | 5905258091952 |
| Parametry | Packaging status | original |
| Parametry | Dominant color | green |
| Parametry | Total capacity | 0 l |
| Parametry | Product height | 16 cm |
| Parametry | Type | not specified |
| Parametry | Number of cartridges included in the kit | 1 |
| Parametry | Cartridge wear indicator | none |






