Prekė: Gliukozės matuoklis SEJOY su lancetėmis. Kategorija: Gliukozės matuokliai.
- Gamintojas: SEJOY
- Modelis: BG-709g
The set includes:
- Sejoy BG-709g glucose meter (incl. battery)
- Sterilance lancets + disposable lancets 10 pcs.
The Sejoy BG-709g glucose meter is used to perform quantitative measurements of glucose concentration in fresh, whole capillary blood. Professional medical personnel can also perform quantitative measurements of glucose levels in venous or neonatal blood. A sample of fresh, whole capillary blood can be taken from the fingertip, a sample of neonatal blood can be taken from the heel. The system is designed for in vitro diagnostics at home and for use by professional medical staff in healthcare facilities to monitor the effectiveness of glycemic control. The system is not intended for the diagnosis of diabetes.
The Sterilance lancet is designed for use with a disposable lancet for capillary blood sampling from peripheral parts of the human body for testing. The LDE4 lancet has 9 depth levels and a knob to set the desired puncture depth. Puncture depth adjustment: number 1 for delicate/thin skin, number 3 for normal skin, number 5 for calloused skin. Further precise adjustments can be made by setting the knob between the numbers.
How the Glucose Meter Works (Using Test Strips):
Contacts: Insert this end of the strip into the test strip port. Push the strip in until you feel resistance.
Tip End: Apply the blood sample to this part.
Confirmation Window: This area allows you to visually confirm the sample.
Important: This glucose meter must only be used with BS-606 test strips. Using other test strips with this meter will result in inaccurate readings.
The test strip measures glucose concentration using an amperometric technique, which relies on a glucose dehydrogenase reaction. When a whole blood or control solution sample is drawn into the tip of the test strip, the glucose in the sample reacts with the reagents in the strip, generating an electrical current. The glucose meter measures the intensity of this electrical current and converts it to the corresponding glucose concentration. The glucose measurement, converted to the equivalent glucose concentration in blood plasma, is then displayed on the meter's screen.
Blood glucose test:
- Hands and puncture site should be washed with an alcohol swab or soapy water. Then rinse thoroughly and dry your hands.
- The tip of the adjustable lancet tip should be positioned at the side of the finger. Press the release button and then, after the puncture, move the lancer away from your finger. The lancet should be set aside and wait a few seconds for a drop of blood to form.
- In order to obtain a round drop of blood, gently squeeze your finger. The first drop should be discarded. Do not measure if blood is smeared or leaking. Wipe the puncture area and gently squeeze another drop of blood or puncture a new area
Important health-related information:
- Patients undergoing oxygen therapy may get inaccurate results.
- Some people with diabetes do not experience symptoms of low blood sugar (hypoglycemia). Others, i.e. children, unconscious persons or people with certain types of disabilities may not be able to communicate their symptoms to caregivers. For these reasons, you should not change any therapy before consulting your doctor.
- After opening a new pack of test strips or if the result is suspected to be incorrect, a follow-up test should be performed. Performing a control test allows you to determine that the glucose meter and test strips are working properly.
- DO NOT CHANGE TREATMENT BASED ON A SINGLE TEST RESULT INCONSISTENT WITH WELL-BEING OR IF YOU SUSPECT THAT THE TEST RESULT MAY BE ABNORMAL. If the test result is inconsistent with your well-being despite following the instructions in this manual, follow your doctor’s instructions or contact your doctor.
- Children should be taught proper handling of the glucose meter and any other medical devices.
- Serious dehydration or loss of water can result in falsified (understated) test results. If you think you may be dehydrated, contact your doctor immediately.
- If, despite following all the instructions in this manual, you still have symptoms inconsistent with the results of the examination or if you have questions, you should consult your doctor.
- The system is intended for use with fresh, whole capillary blood, venous blood or neonatal blood.
- The results obtained at an altitude above 3048 meters above sea level may be inaccurate.
- BS-606 test strips: hematocrit higher than 70% will affect the test results. Contact your doctor to determine the haematocrit.
- Some substances may cause falsification of measurement results performed by enzymatic tests.
Note:
- Use BS-606 test strips only.
- Before testing, make sure that the glucose meter and test strips have roughly the same temperature.
- The test shall be performed within the operating temperature range of 5⁰C~45⁰C. The most accurate results shall be obtained during the test at room temperature of 20⁰C~25⁰C.
- To avoid contamination and damage, close the vial tightly immediately after use.
- Store unused strips only in the original vial.
- The test strip vial should not be opened before being ready to remove the strap and perform the test. Use the test strip immediately after removal from the vial.
- The used test strip should not be returned to the vial.
- Do not reuse the test strip into which blood or control fluid has been previously introduced. Test strips are a single-use product.
- The first time you open the vial with the test strips, write the date of opening on the vial label. Discard the vial 6 months after the first opening date.
Maintenance of the glucose meter:
Avoid contaminating the test strip port with dirt, dust, blood, control fluid, water or other liquids.
Note: Never immerse the glucose meter in water or other liquids. This can result in incorrect results or a glucose meter failure.
Storage:
After each use, the glucose meter should be stored in a case, in a cool, dry place at a temperature in the range of -20⁰C~55⁰C. Do not store in the refrigerator. Protect from direct sunlight and heat. Immediately after use, close the lid of the test strips and/or control fluid tightly to avoid contamination or damage.
Manufacturer: Sejoy Biomedical Co., Ltd.
Advertising entity: DIATHER Petrusewicz Sp. K.
Authorised representative: Shanghai International Holding Corp.Gmbh
These products are CE marked with the number of the notified body (0197). The CE marking indicates that the product has been tested by the manufacturer and found to comply with EU health, safety and environmental requirements.
Both products have an EU declaration of conformity - it meets the requirements of the European Union.
It is a medical device for self-control.
The products are accompanied by a label and an instruction manual in Polish.
NOTE: due to the special storage conditions of the product (from -20°C to 55°C. ) in case of negative or very high temperatures outside, it is recommended to choose the form of delivery by courier, instead of a parcel locker.
Specifications
| Group | Name | Value |
|---|---|---|
| Parametry | Condition | new |
| Parametry | Invoice | With VAT invoice |
| Parametry | Medical device | yes |
| Parametry | Medical device type | medical device or in-vitro diagnostic medical device |
| Parametry | Manufacturer of a medical device | Sejoy Biomedical Co., Ltd. |
| Parametry | Authorized representative | Shanghai International Holding Corp.Gmbh |
| Parametry | Measurement | glucose |
| Parametry | Brand | SEJOY |
| Parametry | Model | BG-709g |
| Parametry | EAN (GTIN) | 5902205136872 |
| Parametry | Packaging status | original |
| Parametry | Certificates of conformity | CE |
| Parametry | Average measurement | of 7 days,from 14 days,of 28 days |
| Parametry | Additional features | automatic coding,Bluetooth,ambient temperature sensor,blood sucking test strips,illuminated display,audio test reminder,average value of measurement results,puncture depth choice,measurement unit selection |
| Parametry | Set components | batteries,case,lancets,injector |