Accutrend Plus glucose meter - glucose, cholesterol, triglycerides, lactic acid

Accutrend® Plus

One portable camera - four parameters

Accutrend Plus is an apparatus that performs quantitative determinations of glucose, cholesterol, triglycerides and lactic acid directly from capillary blood. Roche belts specially designed for this purpose are used to determine each of these parameters.

Accutrend Plus – a quick and simple assessment of cardiovascular risk factors

Total cholesterol, triglycerides and glucose in the blood: the most important parameters for diagnosis and monitoring of cardiovascular diseases.

Lactic acid: a key parameter for assessing the degree of fatigue after exercise, rehabilitation and care in critical cases.

Accutrend Plus is designed so that it can be used outside the laboratory - e.g. in the doctor's office or in the hospital. It can also be used to take measurements at home or while playing sports. Determinations are made of capillary blood, and the results are given immediately.

Principle of operation

The Accutrend Plus measures the intensity of the reaction coating of the test strip using a reflection photometer and calculates the concentration of the parameter in the sample using a series-specific algorithm. The result is displayed in mg/dl or mmol/l (for lactic acid only in mmol/l) and stored in the camera memory automatically with the date, time and additional information. The camera stores up to 100 results for each parameter.

Key benefits

  • Easy to use: Conveniently label cholesterol, triglycerides, blood glucose, and lactic acid from capillary blood using Roche Diagnostics test strips. Test strips can be stored at room temperature.
  • Results obtained in a short time:

Cholesterol - 180 seconds

triglycerides - 174 seconds

glucose - 12 seconds

lactic acid - 60 seconds

  • Built-in security: Coding strips for series identification and parameter recognition.
  • User-help storage of results to manage and monitor results. You can store up to 100 results along with the date, time and additional information for each parameter.
  • Accurate results: High precision and accuracy across the entire measuring range for all parameters.

Unique test strip technology

Accutrend Plus uses specially designed test strips for glucose (Accutrend Glucose), cholesterol (Accutrend Cholesterol), triglycerides (Accutrend Triglycerides) and lactic acid determinations of exceptional quality. The test strips are made up of the following elements:

  • yellow protective mesh soaked with surfactant (application field)
  • glass fibre layer separating blood cells
  • reaction coating in which a colour reaction takes place
  • barcode on the bottom that the camera reads to confirm the type of test strip, i.e. Compliance of the batch number on the test strip with the code stored in the camera.

Built-in security

  • Thanks to the built-in security features, Accutrend Plus performs safety checking procedures to prevent potential errors and malfunctions and ensure accurate results.
  • The Accutrend Plus allows you to apply blood to the test strip inserted into the camera or outside the camera, e.g. when performing multiple markings.
  • Coding strips for identifying a series of test strips and recognizing parameters are used to calibrate the device, which ensures even greater safety and proper operation of the camera.
  • Accutrend Control Chol (cholesterol), Accutrend Control GLU (glucose), Accutrend Control TG (triglycerides) and BM-Control Lactate (lactic acid) control solutions can be used to further check the functioning of the apparatus.

Fast and accurate result in three steps

1. Turning on the camera

Turn on the camera and slide the test strip into the guide. The flashing arrow signals that the lid of the measuring chamber must be opened to apply blood.

2. Blood application

Take a drop of blood from your fingertip and apply it to the yellow application field within 15 seconds. Do not touch the application field with your finger. Blood can also be applied outside the camera. (follow the instructions in the Accutrend Plus manual)

3. Measurement

Close the cover of the measuring chamber and wait for the result. All further actions are performed automatically by the camera. When the reaction is complete, the result will appear on the display. Values outside the measuring range will be displayed as “Hi” (above the measuring range) or “Lo” (below the measuring range).

Technical data

Measuring temperature ranges

Depending on the parameter:

Cholesterol and triglycerides: 18-30 °C Glucose: 18-32 °C

Lactic acid: 15-35 °C

Measuring ranges

Blood glucose: 20 - 600 mg/dL (1,1 – 33,3 mmol/L)

Cholesterol: 150 - 300 mg/dL (3,88 – 7,76 mmol/L)

Triglycerides: 70 – 600 mg/dL (0,80 – 6,86 mmol/L)

Lactic acid: 0,8 – 21,7 mmol/l (whole blood), 0,7 – 26 mmol/l (plasma)

Temperature range

-25 °C - +70 °C

Relative humidity

10 – 85% (without condensation)

Material for testing

One drop of fresh capillary blood *

Memory capacity

100 results; possible recording with date, time and additional information for each parameter

Test principle

Reflection photometry

Dimensions

154 x 81 x 30 mm

Weight

140 g without batteries

Automatic shutdown

After 2 minutes if no button is pressed

Power Requirements

4 AAA 1,5 V alkaline batteries are enough to take more than 1000 measurements (new batteries)

Isolation

Class III

* Detailed information is provided in the product leaflet.

Accutrend® Plus

Frequently Asked Questions

1. Are the results reported by Accutrend Plus reliable?

2. Does using Accutrend Plus require special training?

3. Is Accutrend Plus useful for patients coming to see a doctor?

4. Why should lactic acid concentration be measured using a portable apparatus when performing physical exercise?

1. Are the results reported by Accutrend Plus reliable?

The results given by the camera are reliable for many reasons. The first is to use high quality test strips. In addition, studies have shown that the results reported by the apparatus are comparable to those obtained using recognised laboratory methods throughout the measurement range. What’s more, the security built into the camera additionally supports the proper functioning of the Accutrend Plus camera.

2. Does using Accutrend Plus require special training?

The Accutrend Plus is very easy to use. To take the measurement, simply turn on the camera, insert the test strip, apply a drop of blood and close the cover of the measuring chamber. The camera can be used by a person who is a specialist in the field of medicine, as well as a person performing measurements on their own. No specific training is necessary to use the apparatus (the apparatus meets the safety requirements of DIN EN 61010-1 and the requirements of the EU Directive on in vitro diagnostic medical equipment 98/79/EG).

3. Is Accutrend Plus useful for patients coming to see a doctor?

Many patients treated in primary care centers have dyslipidaemia, metabolic syndrome, or diabetes. Diagnostic tests performed in such centers can significantly improve the diagnosis and treatment of patients with elevated levels of lipids or glucose in the blood. Accutrend Plus gives the results immediately, which allows you to discuss the risk profile of cardiovascular disease and treatment with the patient during the same visit. Your doctor may also take your Accutrend Plus with you on home visits.

4. Why should lactic acid concentration be measured using a portable apparatus when performing physical exercise?

Determination of lactic acid in the blood allows you to control the intensity of exercise and adjust it to the values obtained. Thanks to this, you can reduce the risk of fatigue and injuries – not only in competitive sports, but also in recreational exercises.

Specifications

Group Name Value
Parametry Condition new
Parametry Invoice Without VAT invoice
Parametry Medical device yes
Parametry Medical device type accessories for a medical device or a product without an intended medical purpose
Parametry Manufacturer of a medical device Roche
Parametry Brand Accu-Chek
Parametry Model accutrend plus
Parametry Blood sample volume 0.7 μl
Parametry Measurement time 7 s
Parametry Average measurement from 14 days
Parametry Number of memorized measurements 450
Parametry Number of strips 10
Parametry Number of lancets 10
Parametry Additional features audible alarm
Parametry Set components batteries
Parametry Power supply batteries
Parametry EAN (GTIN) 4015630936748
Parametry Measurement cholesterol,glucose