Gliukozės matuoklio juostelės ACCU-CHEK PERFORMA, 2 x 50 vnt.


Kaina:
Akcijos kaina€37,85
Sandėlys:
Yra sandėlyje

Trumpai apie prekę

Prekė: Gliukozės matuoklio juostelės ACCU-CHEK PERFORMA, 2 x 50 vnt.. Kategorija: Gliukozės matuokliai.

  • Gamintojas: Accu-Chek
  • Modelis: ACCU-CHEK PERFORMA

The Accu-Chek Performa strip test is a medical device.

Easy-to-use strip tests are used to determine glucose concentration in the blood.

Useful in self-control.

Indications

Indications for use:

To measure blood glucose

Action

To measure blood glucose levels.

How to use Accu-Chek Performa

Tip: If you need an activation key for your glucose meter, contact Roche to get the activation key.

With peripheral circulatory disorders, self-checking blood glucose levels may not be the right solution. Please consult your doctor.

Wash your hands in warm soapy water. Rinse and dry completely.

Prepare the lancing device.

Check the expiration date of the strip tests on the strip test container. Do not use strip tests after their expiry date.

Insert the strip test into the glucose meter according to the direction of the arrows. The glucose meter will turn on.

Get a drop of blood with a lancer.

Apply a drop of blood to the front edge of the yellow striped text mock-up. Do not apply blood to the top of the strip test. The blinking symbol indicates that there is already enough blood in the strip test.

Warnings about the use of Accu-Chek Performa

This is a medical device. Use it according to the instructions for use or label.

Blood galactose > 15 mg/dL (> 0,83 mmol/L) leads to an erroneous overestimation of glucose measurements.

Lipemic samples (triglycerides) > 1800 mg/dL (> 20,3 mmol/L) may lead to an overestimation of glucose measurement results.

Intravenous administration of ascorbic acid leading to blood acid > 3 mg/dL (> 0,17 mmol/L) will result in an overestimation of blood concentration results.

In peripheral circulatory disorders, it is not recommended to take capillary blood from standard sites, as there is a possibility that physiological glucose levels will not be correctly determined. This includes cases such as severe dehydration due to keronic acidosis in diabetes or hyperglycemic-hypermolar syndrome, hypotension, shock, decompensated NYHA class IV cardiac insufficiency or atherosclerosis of the lower extremities.

The hematocrit value should be in the range of 10-65%. Please consult your doctor if the value of your own hematocrit is unknown.

The system is tested for use at heights up to 309 meters.

Useful in self-control.

Content

2 X 50 strip tests and leaflets

Storage method: 15°C - 25°C

Manufacturer: ROCHE

Specifications

Group Name Value
Parametry Condition new
Parametry Invoice Without VAT invoice
Parametry Medical device yes
Parametry Medical device type medical device or in-vitro diagnostic medical device
Parametry Manufacturer of a medical device Accu-chek
Parametry Measurement glucose
Parametry Brand Accu-Chek
Parametry Model ACCU-CHEK PERFORMA
Parametry Average measurement not specified
Parametry Additional features none
Parametry Set components stripes
Parametry EAN (GTIN) 15051978000587
Parametry Batteries included no

Pristatymo terminas kiekvienai prekei nurodomas prie kainos bloko.
Pristatymas visoje Lietuvoje: nemokamas.

Susijusios prekės

Nesenai žiūrėtos