{"product_id":"vandens-kietumo-matuoklis-tds-ec-druskingumo-testeris","title":"Vandens kietumo matuoklis TDS EC druskingumo testeris","description":"\u003ch2\u003eTrumpai apie prekę\u003c\/h2\u003e\u003cp\u003ePrekė: Vandens kietumo matuoklis TDS EC druskingumo testeris. Kategorija: Atvirkštinio osmoso sistemos.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGamintojas:\u003c\/strong\u003e Tessa\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModelis:\u003c\/strong\u003e C-100\u003c\/li\u003e\n\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003eMeasurement of the total amount of all substances dissolved in water (ppm), conductivity (µS), salinity (%), specific gravity (IU) and temperature (°C)\u003c\/li\u003e\n\u003cli\u003eConductivity \u003cb\u003eEC\u003c\/b\u003e (Electrical Conductivity)\u003c\/li\u003e\n\u003cli\u003eWater pollution (measurement of chemical concentration) \u003cb\u003eTDS\u003c\/b\u003e (Total Dissolves Solids)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSalinity\u003c\/b\u003e (salt)\u003c\/li\u003e\n\u003cli\u003eSpecific gravity \u003cb\u003eS.G.\u003c\/b\u003e (Specific Gravity)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eTemperature measurement\u003c\/b\u003e in degrees °C or °F\u003c\/li\u003e\n\u003cli\u003eMeasurement memory - hold function\u003c\/li\u003e\n\u003cli\u003eAutomatic change of measuring ranges\u003c\/li\u003e\n\u003cli\u003eLarge, easy-to-read LCD display with backlight\u003c\/li\u003e\n\u003cli\u003eBattery saving - auto-off function (turns off the meter after 5 minutes of inactivity)\u003c\/li\u003e\n\u003cli\u003eAutomatic liquid temperature compensation (ATC)\u003c\/li\u003e\n\u003cli\u003eBrand new product (calibrated - calibration solution HANNA HI 7031L 1413 µS\/cm)\u003c\/li\u003e\n\u003cli\u003eManual calibration up to three points: 1413µS\/cm; 12.88mS\/cm; 111.8µS\/cm)\u003c\/li\u003e\n\u003cli\u003eSimple operation\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eThe exception to the use of the TDS meter is a water softener, this is due to the specificity of the tester's operation.\u003c\/b\u003e \u003cb\u003eSalt tablets are used in softeners, the meter does not distinguish ions, but counts and sums them.\u003c\/b\u003e \u003cb\u003eSo the measurement of contamination behind the softener will be higher than before.\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eOther methods of measuring water hardness are used at the output of the softener, e.g.\u003c\/b\u003e \u003cb\u003edroplet\/strip water hardness testers.\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eEC:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRange: 0 ~ 10000 µS\/cm; 10.01 ~ 19.99 mS\/cm; 20.1 ~ 400 mS\/cm\u003c\/li\u003e\n\u003cli\u003eResolution: 1µS\/cm; 0.1mS\/cm\u003c\/li\u003e\n\u003cli\u003eAccuracy: ± 2%\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eTDS:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRange: 0 ~ 1000 ppm; 1000 ppm ~ 10000 ppm; 10.1 ~ 200.0 ppt\u003c\/li\u003e\n\u003cli\u003eResolution: 1 ppm; 0.1 ppt\u003c\/li\u003e\n\u003cli\u003eppm (parts per million) = parts per million\u003c\/li\u003e\n\u003cli\u003eppt (parts per thousand) = parts per thousand\u003c\/li\u003e\n\u003cli\u003eAccuracy: ±2%\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eSalinity [Salinity]:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRange: 0.00 ~ 25.00 %\u003c\/li\u003e\n\u003cli\u003eResolution: 0.01 %\u003c\/li\u003e\n\u003cli\u003eAccuracy: 0.01 ~ 5.00% (±0.1%); 5.10 ~ 25.00% (±1%)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eRight weight [S.G.]:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eScope\u003cb\u003e:\u003c\/b\u003e 1.000 ~ 1.222\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eTemperature:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eTemperature measuring range: 0,1 ~ +80 °C\u003c\/li\u003e\n\u003cli\u003eMeasurement resolution: 0,1 °C\u003c\/li\u003e\n\u003cli\u003eAccuracy: ± 0,5 °C\u003c\/li\u003e\n\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003eTDS\/EC ratio: 0 .5\u003c\/li\u003e\n\u003cli\u003eOperating temperature: 0 ~ +80 °C\u003c\/li\u003e\n\u003cli\u003eRelative humidity: \u0026lt; 90 %\u003c\/li\u003e\n\u003cli\u003eDimensions: 159x34x16 mm\u003c\/li\u003e\n\u003cli\u003eWeight: 60g (79g whole set)\u003c\/li\u003e\n\u003cli\u003ePower supply: 3*1,5V LR44 (batteries included)\u003c\/li\u003e\n\u003c\/ul\u003e\u003col\u003e\n\u003cli\u003eBattery compartment 3*1,5V LR44\u003c\/li\u003e\n\u003cli\u003eLCD display\u003c\/li\u003e\n\u003cli\u003eStop button for measuring and changing °C\/°F (after holding for 4 seconds)\u003c\/li\u003e\n\u003cli\u003eOn button\u003c\/li\u003e\n\u003cli\u003eChange of measurement mode and calibration (after holding for 4 seconds)\u003c\/li\u003e\n\u003cli\u003eMeasuring electrode\u003c\/li\u003e\n\u003cli\u003eProtective cap\u003c\/li\u003e\n\u003c\/ol\u003e\u003cul\u003e\n\u003cli\u003eElectronic tester \u003cb\u003eTDS\/EC\/Salinity\/S.G. \u003c\/b\u003ewith ATC function\u003c\/li\u003e\n\u003cli\u003eProtective cap\u003c\/li\u003e\n\u003cli\u003eCover \/ case\u003c\/li\u003e\n\u003cli\u003eDetailed instruction in English\u003c\/li\u003e\n\u003cli\u003eDetailed instruction in Polish can be downloaded from the \"\u003cb\u003eAdditional information\"\u003c\/b\u003e tab located at the bottom of the page.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003edetermination of the amount of substances dissolved in water\u003c\/li\u003e\n\u003cli\u003ewater temperature measurement\u003c\/li\u003e\n\u003cli\u003eassessment of osmotic membrane efficiency\u003c\/li\u003e\n\u003cli\u003eMarine and freshwater aquaristics\u003c\/li\u003e\n\u003cli\u003efood and chemical industry\u003c\/li\u003e\n\u003cli\u003elaboratory tests, pharmacy\u003c\/li\u003e\n\u003cli\u003ewater supply, wastewater testing\u003c\/li\u003e\n\u003cli\u003ecamping, travelling\u003c\/li\u003e\n\u003cli\u003ehydroponic crops\u003c\/li\u003e\n\u003cli\u003eswimming pools and spas\u003c\/li\u003e\n\u003cli\u003egastronomy\u003c\/li\u003e\n\u003cli\u003eagriculture\u003c\/li\u003e\n\u003cli\u003ewherever assessment of water quality and pollution is needed\u003c\/li\u003e\n\u003cli\u003esources of fresh water from streams, rivers, wells, rainwater reservoirs\u003c\/li\u003e\n\u003c\/ul\u003e\u003col\u003e\n\u003cli\u003eRemove the protective cap. Turn on the meter with the \"ON\/OFF\" button\u003c\/li\u003e\n\u003cli\u003eImmerse the meter in the test liquid (do not cross the immersion line - the height of the protective cap).\u003c\/li\u003e\n\u003cli\u003eGently stir and wait for the reading to stabilize (no changes for 5 seconds).\u003c\/li\u003e\n\u003cli\u003eRead the value from the display or press the \u003cb\u003eHOLD\u003c\/b\u003e button and read the result away from the measured liquid.\u003c\/li\u003e\n\u003cli\u003eAfter the measurement, rinse the electrodes with water and wipe with a cloth.\u003c\/li\u003e\n\u003cli\u003eTurn off the meter with the \"ON\/OFF\" button.\u003c\/li\u003e\n\u003cli\u003ePut on a protective cap.\u003c\/li\u003e\n\u003c\/ol\u003e\u003cp\u003ePressing the \u003cb\u003eMODE \u003c\/b\u003e key allows you to choose between 4 display modes:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eEC - µs\/cm \u0026amp; °C\u003c\/li\u003e\n\u003cli\u003eTDS - ppm \u0026amp; °C\u003c\/li\u003e\n\u003cli\u003eSalt - %\u0026amp; °C\u003c\/li\u003e\n\u003cli\u003eS.G.- IU \u0026amp; °C\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eBelow are links with descriptions and conversions between liquid contamination\/hardness scales (6 main scales):\u003c\/h2\u003e\u003cp\u003ehttp:\/\/www.mpwik.org\/?page_id=174\u003c\/p\u003e\u003cp\u003ehttps:\/\/pl.wikipedia.org\/wiki\/Twardo%C5%9B%C4%87_wody\u003c\/p\u003e\u003cp\u003e\u003cb\u003eATC function \u003c\/b\u003e(\u003cb\u003eA\u003c\/b\u003eutomatic \u003cb\u003eT\u003c\/b\u003eemperature \u003cb\u003eC\u003c\/b\u003eompensation) - temperature measurement and compensation indication of the meter in the range of 0-50°C. This gives us a more accurate result.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eThe TDS\/EC\/Salinity\/S.G.\u003c\/b\u003e meter complies with EU directives and is marked with the \u003cb\u003eCE\u003c\/b\u003e mark. In addition, the meter is made of materials that meet the strict requirements of the EU \u003cb\u003eROHS\u003c\/b\u003e directive.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eDo not immerse the meter in the solution above the immersion line to avoid damaging the circuits.\u003c\/li\u003e\n\u003cli\u003eTemperature: The meter cannot be used to measure high temperature water.\u003c\/li\u003e\n\u003cli\u003eFlow rate: The meter cannot be used to measure water during its flow.\u003c\/li\u003e\n\u003cli\u003eThe protective cap can be used as a handheld measuring container.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe \u003cb\u003eTDS\/EC\/Salinity\/S.G. \u003c\/b\u003e meter is an easy-to-use tool for quickly and accurately indicating the number of dissolved solids in liquids. Dissolved solids are mostly inorganic salts such as sodium, calcium, magnesium and potassium cations along with chlorides, bicarbonates, carbonates, phosphates, sulfates and nitrate anions.\u003c\/p\u003e\u003cp\u003eThe higher the measurement value (hard water), the worse the absorption of water by the body's cells and the greater the likelihood of its negative impact on human health\u003c\/p\u003e\u003cp\u003e\u003cb\u003eAccording to Polish standards, water above 500 ppm is not suitable for drinking\u003c\/b\u003e.\u003c\/p\u003e\u003cp\u003eThe exception to the use of the tester is a water softener, which results from its specificity of operation. Salt tablets are used in softeners, the meter does not distinguish ions, but counts and sums them. Thus, other methods of measuring water hardness are used at the output of the softener, e.g. Striped water hardness testers\u003c\/p\u003e\u003cp\u003eTDS meters measure EC (electrical conductivity) of liquids. Dissolved salts and minerals conduct electricity, the more minerals in the water sample, the higher the conductivity. The meter then converts the EC reading to TDS using the appropriate conversion rate.\u003c\/p\u003e\u003cp\u003eHigh levels of TDS may indicate a large amount of organic material in the water and a lower ability of water to retain oxygen. This means that water changes are required, even if nitrate levels are low.\u003c\/p\u003e\u003cp\u003eHigh concentrations of TDS can reduce water clarity, contribute to reducing photosynthesis, combine with toxic compounds and heavy metals, and lead to an increase in water temperature.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eGroup\u003c\/th\u003e\n\u003cth\u003eName\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003enew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eInvoice\u003c\/td\u003e\n\u003ctd\u003eWith VAT invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTessa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eC-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eManufacturer code\u003c\/td\u003e\n\u003ctd\u003eC-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003ePackaging status\u003c\/td\u003e\n\u003ctd\u003eoriginal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"BIELASTO_S_C","offers":[{"title":"Default Title","offer_id":45959678984252,"sku":"9757996326","price":44.47,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0618\/2161\/6188\/files\/Meter-Tester-TDS-EC-Water-Hardness-Electronic-Salinity-Conductometer.jpg?v=1786087579","url":"https:\/\/market365.lt\/products\/vandens-kietumo-matuoklis-tds-ec-druskingumo-testeris","provider":"Market365","version":"1.0","type":"link"}