{"product_id":"vakuuminis-slegio-siurblys-stabdziu-sistemai-yato-yt-0674","title":"Vakuuminis slėgio siurblys stabdžių sistemai Yato YT-0674","description":"\u003ch2\u003eTrumpai apie prekę\u003c\/h2\u003e\u003cp\u003ePrekė: Vakuuminis slėgio siurblys stabdžių sistemai Yato YT-0674. Kategorija: Įrankių rinkiniai.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGamintojas:\u003c\/strong\u003e Yato\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModelis:\u003c\/strong\u003e YT-0674\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003e✔️ This vacuum and pressure pump is a versatile tool for diagnosing systems in cars and other technical equipment\u003c\/b\u003e that rely on pressure or vacuum for operation.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e✔️ It comes with accessories that allow it to be used in almost any engine or system.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e✔️ The YT-0674 pump features a switch\u003c\/b\u003e that allows you to generate either vacuum or pressure, depending on its position.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e✔️ Moving the switch towards the pump outlet\u003c\/b\u003e will create a vacuum when pumping.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e✔️ Moving the switch towards the handle\u003c\/b\u003e will create pressure when pumping.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e✔️ Measurement range: \u003c\/b\u003e-1 to 3 bar\u003c\/p\u003e\u003cp\u003e\u003cb\u003e✨ Purpose \/ Application\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eThe m.in diagnostics can be performed with a pump.\u003c\/b\u003e \u003cb\u003ethe following systems and systems:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e✅ Computerized engine control devices:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ebarometric pressure sensor (BARO)\u003c\/li\u003e\n\u003cli\u003ePVC system\u003c\/li\u003e\n\u003cli\u003eExhaust gas recirculation system (EGR)\u003c\/li\u003e\n\u003cli\u003ethick-layer pressure sensors (MAP)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003e✅ Ignition control devices:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003evacuum ignition advance\u003c\/li\u003e\n\u003cli\u003eDelay valve: SDV, RCV\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003e✅ Brake system:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eClassic brakes\u003c\/li\u003e\n\u003cli\u003eABS brakes\u003c\/li\u003e\n\u003cli\u003epneumatic brakes\u003c\/li\u003e\n\u003cli\u003ebrake lines\u003c\/li\u003e\n\u003cli\u003eBrake servo\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003e✅ Other systems:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eair conditioning\u003c\/li\u003e\n\u003cli\u003ecruise control\u003c\/li\u003e\n\u003cli\u003efuel tank and fuel system\u003c\/li\u003e\n\u003cli\u003evacuum door closing system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003e✅ Usage\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDiagnostics of exhaust gas recirculation (EGR) system\u003c\/li\u003e\n\u003cli\u003eThe EGR system valve is an example of a vacuum actuated valve. In the absence of vacuum, the valve is closed and exhaust gases do not escape from the valve. If a vacuum is brought to the valve, it is opened, allowing exhaust gases to recirculate.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003e✅ Diagnostics of thick-layer pressure sensors (MAP)\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAssemble the pump and tank system, as in the case of brake caliper venting, and then connect to the sensor vacuum connection.\u003c\/li\u003e\n\u003cli\u003ePress the pump lever until the hand shows -0,5 bar. Finish pumping and observe the hand, it should be stationary. If the hand moves, it means damage to the MAP sensor.\u003c\/li\u003e\n\u003cli\u003eDuring operation, the MAP sensor sends feedback signals to the control computer. The signal has a frequency between 85 Hz and 160 Hz depending on the vacuum level. A frequency meter is necessary to measure the frequency, it must be connected according to the instructions of the sensor and meter.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003e✅ Ventilation of brake calipers.\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure that the brake system expansion tank is filled with fluid to the nominal volume.\u003c\/li\u003e\n\u003cli\u003eVenting should be carried out in the following order:\u003c\/li\u003e\n\u003cli\u003ebrake pump, if equipped with a vent valve\u003c\/li\u003e\n\u003cli\u003eBrake calipers in order from the nearest brake pump to the furthest\u003c\/li\u003e\n\u003cli\u003eConnect the short flexible hose to the connection located on the bottom of the pump tank cover.\u003c\/li\u003e\n\u003cli\u003eClose the pump tank with the lid.\u003c\/li\u003e\n\u003cli\u003eConnect long flexible wires to the cover connections. The end of one of the long hoses connects to the pump and the other to the vent valve (calamite) of the brake caliper. Use an adapter if necessary.\u003c\/li\u003e\n\u003cli\u003ePress the pump lever 10 - 15 times to create a vacuum in the pump tank.\u003c\/li\u003e\n\u003cli\u003eUnscrew the vent valve by 1\/4 - 1\/2 turn, so that the pump tank fills with liquid to a height of about 5 cm. Tighten the vent valve.\u003c\/li\u003e\n\u003cli\u003eDisconnect the pump hose from the vent valve, the clamp venting procedure is completed.\u003c\/li\u003e\n\u003cli\u003eBefore repeating the venting procedure in the next caliper, empty the pump tank from the brake fluid and replenish the brake fluid level in the brake system to the nominal level.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eWorking pressure:\u003c\/b\u003e 1-3 bar\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMeasurement range:\u003c\/b\u003e -1 ~ 3 bar\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eUnit of measurement:\u003c\/b\u003e PCE\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eWeight:\u003c\/b\u003e 2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eGroup\u003c\/th\u003e\n\u003cth\u003eName\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003enew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eInvoice\u003c\/td\u003e\n\u003ctd\u003eWith VAT invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYato\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eManufacturer code\u003c\/td\u003e\n\u003ctd\u003eYT-0674\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eProduct weight with unit packaging\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eEAN (GTIN)\u003c\/td\u003e\n\u003ctd\u003e5906083906749\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eNumber of items in the set\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"matrixsiedlce","offers":[{"title":"Default Title","offer_id":45724791996476,"sku":"18313084273","price":53.33,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0618\/2161\/6188\/files\/Yato-YT-0674-Vacuum-pressure-pump-for-venting-the-brake-system.jpg?v=1782803857","url":"https:\/\/market365.lt\/products\/vakuuminis-slegio-siurblys-stabdziu-sistemai-yato-yt-0674","provider":"Market365","version":"1.0","type":"link"}