{"product_id":"multifunkcinis-instaliaciju-parametru-matuoklis-sonel-mpi-540-pv-start","title":"Multifunkcinis instaliacijų parametrų matuoklis SONEL MPI-540-PV Start","description":"\u003ch2\u003eTrumpai apie prekę\u003c\/h2\u003e\u003cp\u003ePrekė: Multifunkcinis instaliacijų parametrų matuoklis SONEL MPI-540-PV Start. Kategorija: Detektoriai.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGamintojas:\u003c\/strong\u003e Sonel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModelis:\u003c\/strong\u003e WMPLMPI540PVS\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMultifunctional Electrical Installation Parameter Meter\u003c\/h2\u003e\u003cp\u003e\u003cb\u003eSONEL MPI-540-PV START\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e✅ \u003cb\u003eThe largest touch panel on the market (7”) – extraordinary ergonomics and ease of use\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e✅ \u003cb\u003eRemovable microSD card\u003c\/b\u003e – easily increase memory capacity\u003c\/p\u003e\u003cp\u003e✅ \u003cb\u003eLi-Ion\u003c\/b\u003e battery – longer operation of the meter\u003c\/p\u003e\u003cp\u003e✅ \u003cb\u003eMeasurements of photovoltaic installations in accordance with PN-EN 62446\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e✅\u003cb\u003e Cooperation with the meter\u003c\/b\u003e of sunlight and temperature\u003c\/p\u003e\u003cp\u003e✅ \u003cb\u003eReport on research of photovoltaic installations\u003c\/b\u003e after transferring data to the \u003cb\u003eSonel Electrical Measurements\u003c\/b\u003e program\u003c\/p\u003e\u003cp\u003e✅ \u003cb\u003eReading data of current network parameters\u003c\/b\u003e – immediate evaluation of the tested device\u003c\/p\u003e\u003ch2\u003eWhat's included in the kit?\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003e1 pc.\u003c\/b\u003e \u003cb\u003eMPI-540\u003c\/b\u003e multifunctional electrical \u003cb\u003einstallation parameter meter\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pc.\u003c\/b\u003e \u003cb\u003ePVM-1\u003c\/b\u003e PV \u003cb\u003eAdapter\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pc.\u003c\/b\u003e \u003cb\u003eMC4 adapter\u003c\/b\u003e - banana sockets (set) \u003cb\u003eWAADAMC4\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pc.\u003c\/b\u003e C-PV clamp \u003cb\u003ecable\u003c\/b\u003e \u003cb\u003eWAADACPV\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pc.\u003c\/b\u003e \u003cb\u003eC-PV\u003c\/b\u003e measuring \u003cb\u003eclamps\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pc.\u003c\/b\u003e M-13 \u003cb\u003ecase\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e2 pcs.\u003c\/b\u003e AAA alkaline \u003cb\u003ebattery\u003c\/b\u003e LR03 (24A) 1.5 V \u003cb\u003eWABATAAA\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pc.\u003c\/b\u003e \u003cb\u003eProgram\u003c\/b\u003e for operating power quality analyzers of the PQM and MPI-540 series \u003cb\u003eSonel Analysis 4\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pc.\u003c\/b\u003e Free \u003cb\u003eprogram for downloading data\u003c\/b\u003e from \u003cb\u003eSonel Reader\u003c\/b\u003e meters\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pc.\u003c\/b\u003e Measurement trigger \u003cb\u003eadapter\u003c\/b\u003e (UNI-Schuko plug) \u003cb\u003eWS-03\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pc.\u003c\/b\u003e \u003cb\u003eAdapter\u003c\/b\u003e for rail connector with M4\/M6 thread - set of 4 pcs \u003cb\u003eWAADAM4M64\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pc.\u003c\/b\u003e 1.2 m \u003cb\u003ered\u003c\/b\u003e 1 kV \u003cb\u003ecable\u003c\/b\u003e (banana plugs) \u003cb\u003eWAPRZ1X2REBB\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pc.\u003c\/b\u003e 1.2 m \u003cb\u003eblue\u003c\/b\u003e 1 kV \u003cb\u003ecable\u003c\/b\u003e (banana plugs) WAPRZ1X2BUBB\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pc.\u003c\/b\u003e 1.2 m \u003cb\u003eblack\u003c\/b\u003e \u003cb\u003ecable\u003c\/b\u003e , 1kV, terminated with banana plugs, marked N \u003cb\u003eWAPRZ1X2BLBBN\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pc.\u003c\/b\u003e 15 m \u003cb\u003eblue\u003c\/b\u003e grounding test \u003cb\u003elead\u003c\/b\u003e on a reel (banana plugs) \u003cb\u003eWAPRZ015BUBBSZ\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pc.\u003c\/b\u003e 30 m \u003cb\u003ered\u003c\/b\u003e grounding test \u003cb\u003elead\u003c\/b\u003e on a reel (banana plugs) \u003cb\u003eWAPRZ030REBBSZ\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e2 pcs.\u003c\/b\u003e 30 cm ground \u003cb\u003eprobe\u003c\/b\u003e \u003cb\u003eWASONG30\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pc.\u003c\/b\u003e 1 kV \u003cb\u003eyellow\u003c\/b\u003e blade \u003cb\u003eprobe\u003c\/b\u003e (banana socket) \u003cb\u003eWASONYEOGB1\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pc.\u003c\/b\u003e 1 kV \u003cb\u003ered\u003c\/b\u003e pin \u003cb\u003eprobe\u003c\/b\u003e (banana socket) \u003cb\u003eWASONREOGB1\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pc.\u003c\/b\u003e 1 kV \u003cb\u003eblue\u003c\/b\u003e pin \u003cb\u003eprobe\u003c\/b\u003e (banana socket) \u003cb\u003eWASONBUOGB1\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pc.\u003c\/b\u003e \u003cb\u003eCrocodile clip\u003c\/b\u003e yellow 1 kV 20 A \u003cb\u003eK-02\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pc.\u003c\/b\u003e Red \u003cb\u003ecrocodile clip\u003c\/b\u003e 1 kV 20 A \u003cb\u003eK-0\u003c\/b\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pc.\u003c\/b\u003e \u003cb\u003eCrocodile clip\u003c\/b\u003e black 1 kV 20 A \u003cb\u003eK-01\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pc.\u003c\/b\u003e Li-ion \u003cb\u003ebattery\u003c\/b\u003e 11.1 V 3.4 Ah \u003cb\u003eAKU-15\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pc.\u003c\/b\u003e \u003cb\u003eZ-7\u003c\/b\u003e battery charging \u003cb\u003epower supply\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pc.\u003c\/b\u003e 230 V power \u003cb\u003ecable\u003c\/b\u003e (IEC C7 plug) \u003cb\u003eWAPRZLAD230\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pc.\u003c\/b\u003e \u003cb\u003eCable\u003c\/b\u003e for charging the battery from a 12V car socket \u003cb\u003eWAPRZLAD12SAM\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pc.\u003c\/b\u003e \u003cb\u003eL-2 case\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pc.\u003c\/b\u003e \u003cb\u003eHarness\u003c\/b\u003e for the meter set \u003cb\u003eWAPOZSZEKPL\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pc.\u003c\/b\u003e \u003cb\u003eWAPRZUSB\u003c\/b\u003e USB \u003cb\u003eCable\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pc.\u003c\/b\u003e 4GB microSD \u003cb\u003ecard\u003c\/b\u003e \u003cb\u003eWAPOZMSD4\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pc.\u003c\/b\u003e Sonel \u003cb\u003eWAPOZUSBSTICK\u003c\/b\u003e \u003cb\u003ependrive\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pc.\u003c\/b\u003e \u003cb\u003eWAPOZTPEN\u003c\/b\u003e touchscreen \u003cb\u003epen\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pc.\u003c\/b\u003e \u003cb\u003eWADOKCK\u003c\/b\u003e calibration \u003cb\u003ecertificate\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pc.\u003c\/b\u003e \u003cb\u003e1.2 m yellow 1 kV cable\u003c\/b\u003e (banana plugs) \u003cb\u003eWAPRZ1X2YEBB\u003c\/b\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe calibration certificate is a document issued free of charge during the meter production process.\u003c\/p\u003e\u003cp\u003eConfirms the assignment of metrological properties and the maintenance of measurement traceability.\u003c\/p\u003e\u003cp\u003eIn the calibration certificate, under the date of issue of the document there is a dotted field: \"Date of putting into service\". This is a field left for the user of the device, in which the date of purchase should be entered.\u003c\/p\u003e\u003cp\u003eThe entered purchase date can be used to determine the next calibration date based on the manufacturer's recommendation below:\u003c\/p\u003e\u003cp\u003eIt is recommended to carry out the next metrological confirmation (calibration) within 12 months from the date of purchase, but no later than 24 months from the date of production\/testing.\u003c\/p\u003e\u003cp\u003eThe next metrological control is carried out by the Research and Calibration Laboratory Sonel SA, and the issued document is called the Calibration Certificate.\u003c\/p\u003e\u003ch2\u003eMPI-540-PV Start\u003c\/h2\u003e\u003cp\u003e✅ \u003cb\u003eParameters measured in class S \u003c\/b\u003estandards PN-EN 61000-4-30 – \u003cb\u003ehigh accuracy of measurements\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e✅ \u003cb\u003eEnergy loss calculator\u003c\/b\u003e – quick diagnosis of potential savings\u003c\/p\u003e\u003cp\u003e✅ \u003cb\u003eMeasurement of all parameters of shock protection – one device instead of several\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e✅ \u003cb\u003eQuick short-circuit loop measurement\u003c\/b\u003e with RCD switch without triggering (up to a few seconds) – time saving\u003c\/p\u003e\u003cp\u003e✅ \u003cb\u003eSelf-tests\u003c\/b\u003e – possibility of automatic measurements in sequence – simplification of measurements\u003c\/p\u003e\u003cp\u003e✅ \u003cb\u003eFast track from measurements to report\u003c\/b\u003e – saving time\u003c\/p\u003e\u003ch2\u003eFEATURES\u003c\/h2\u003e\u003cp\u003e✅ The \u003cb\u003eMPI-540-PV\u003c\/b\u003e instrument can record the electrical energy quality parameters 50\/60 Hz\u003cb\u003e in class S of EN 61000-4-30:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cb\u003evoltages L1, L2, L3 – average values in the range up to 500 V,\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003ecurrents L1, L2, L3 – average values, current measurement in the range up to 3 kA (depending on the current clamps used),\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003efrequency in the range of 40 Hz – 70 Hz,\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eactive power (P), reactive power (Q), apparent power (S),\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003epower factor (PF), cos, tg,\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eharmonic (up to 40th in voltage and current),\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eTHD harmonic distortion factor for current and voltage,\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003erecording of events for current and voltage,\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eenergy flow – 4 quadrants.\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003ePhotovoltaics under supervision\u003c\/h2\u003e\u003cp\u003e✅ \u003cb\u003eWe will perform a complete set of tests on the DC and AC\u003c\/b\u003e side – in accordance with the guidelines of PN-EN 62446.\u003c\/p\u003e\u003cp\u003e✅\u003cb\u003e By measuring the parameters associated with the photovoltaic installation\u003c\/b\u003e, the instrument will automatically convert them to STC (Standard Test Conditions) reference conditions.\u003c\/p\u003e\u003cp\u003e✅ Measurements of \u003cb\u003evoltage\u003c\/b\u003e, \u003cb\u003ecurrents \u003c\/b\u003e and \u003cb\u003epower \u003c\/b\u003e on the AC and DC side of the inverter will allow you to verify its efficiency.\u003c\/p\u003e\u003cp\u003e✅ \u003cb\u003eRecording the results in the meter memory \u003c\/b\u003ewill allow you to perform a report of the tests carried out in the \u003cb\u003eSonel Electrical Measurements program.\u003c\/b\u003e\u003c\/p\u003e\u003ch2\u003eComprehensive Network Parameter Analysis\u003c\/h2\u003e\u003cp\u003e✅ The built-in three-phase recorder allows for **monitoring the current network status** and **recording** its parameters such as **voltage, current, power, harmonics, and THD.**\u003c\/p\u003e\u003cp\u003e✅ The meter enables **reading selected values** and **displaying their real-time graphical presentation.**\u003c\/p\u003e\u003cp\u003e✅ Parameters are measured **independently of the recording saved to the memory card**. The device can display:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e**Voltage and current waveform graphs (oscilloscope),**\u003c\/li\u003e\n\u003cli\u003e**Voltage and current graphs over time,**\u003c\/li\u003e\n\u003cli\u003e**Phasor diagrams,**\u003c\/li\u003e\n\u003cli\u003e**Measurements of multiple parameters in tabular form,**\u003c\/li\u003e\n\u003cli\u003e**Harmonic graphs** for **current** and **voltage.**\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e✔ \u003cb\u003eSafety and conditions of use\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eMeasuring category according to PN-EN 61010: \u003c\/b\u003e II 1000 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDegree of protection: \u003c\/b\u003eIP51\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eType of insulation according to PN-EN 61010-1 and IEC 61557: \u003c\/b\u003edouble\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eWorking temperature: \u003c\/b\u003e0...+45°C\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e✔ \u003cb\u003eMemory and communication\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eMeasurement results memory: \u003c\/b\u003eunlimited\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eResults transmission: \u003c\/b\u003eUSB 2.0\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e✔ \u003cb\u003eOther information\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eQuality standard – development, design and production: \u003c\/b\u003eISO 9001\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eThe product meets the requirements of EMC (emission for the industrial environment) according to the following standards: \u003c\/b\u003ePN-EN 61326-1 PN-EN 61326-2-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecification – 3-phase recorder\u003c\/h2\u003e\u003cp\u003e✔ \u003cb\u003eIndications in the table:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cb\u003eA- Parameter \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eB- Measuring range \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eC- Maximum resolution \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eD- Basic Error \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e1- AC voltage (TRMS)\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e2- AC TRMS\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e3- Frequency\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e4- Active, reactive, apparent and deformation power\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e5- Active, passive and apparent energy\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e6- cos and power factor (PF)\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e7- Harmonic\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e7.1- Voltage\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e7.2- Current \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e8- THD\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e8.1 Voltage\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e8.2 Current \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e9- Asymmetry coefficient \u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecification – electrical installation parameters\u003c\/h2\u003e\u003cp\u003e✔ \u003cb\u003eTable symbols:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cb\u003eA- Measurement functions\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eB- Measuring range\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eC- Display Range\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eD- Resolution\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eE- Accuracy (% wm + digits)\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e1- Fault loop impedance\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e1.1 Short circuit loop ZL-PE, ZL-N, ZL-L\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e1.2- ZL-PE short circuit loop in RCD mode\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e2- Measurements of RCD parameters, RCD tripping test and measurement of tripping time tA measuring current 0.5 In, 1 In, 2 In, 5 In\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e2.1- RCD of general type and short-time delay\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e2.2- Selective RCD\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e3- Measurement of RCD tripping current IA measuring current 0.2 In…2.0 In\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e3.1- for sinusoidal differential current (AC type)\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e3.2- for 1-way differential current and 1-way with 6 mA DC bias (type A)\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e3.3- for direct differential current (type B)\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecification – parameters of electrical installations\u003c\/h2\u003e\u003cp\u003e✔ \u003cb\u003eIndications in the table: \u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cb\u003eA- Measurement functions\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eB- Measuring range\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eC- Display range\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eD- Resolution\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eE- Accuracy (% w.m. + digits)\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e1- Grounding resistance\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e1.1- 3-wire and 4-wire method\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e1.2- 3-wire method + clamps\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e1.3- 2-clamp method\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e2- Land resistivity\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e3- Insulation resistance\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e3.1- Measuring voltage 50 V\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e3.2- Measuring voltage 100 V\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e3.3- Measuring voltage 250 V\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e3.4- Measuring voltage 500 V\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e3.5- Measuring voltage 1000 V\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e4- Resistance of protective and compensating conductors\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e4.1- Measurement of continuity of protective and compensatory connections with current 200 mA\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e4.2- Small current resistance measurement\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCONSTRUCTION\u003c\/h2\u003e\u003col\u003e\n\u003cli\u003e\u003cb\u003eStarting the measurement procedure \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eTouch electrode\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eTouch screen\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eEar to fasten suspenders \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eTurn the meter on and off \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eES socket for measuring ground resistance and ground resistivity \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eN socket of the recorder \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eMeasuring sockets \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eClamp sockets I1, I2, I3- recorder, Re-ground measurement\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\u003cul\u003e\n\u003cli\u003e\u003cb\u003eA- Back\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eB- Save\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eC- Show last measurement\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eD- To the main menu\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eE- Select \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eF- Show additional icons\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eG- Add position\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eH- Edit item \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eI- Search \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eJ- Delete item \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eK- Close MENU\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eGroup\u003c\/th\u003e\n\u003cth\u003eName\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003enew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eInvoice\u003c\/td\u003e\n\u003ctd\u003eWith VAT invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSonel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eKind\u003c\/td\u003e\n\u003ctd\u003evoltage detector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003erechargeable battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eManufacturer code\u003c\/td\u003e\n\u003ctd\u003eWMPLMPI540PVS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eEAN (GTIN)\u003c\/td\u003e\n\u003ctd\u003e5907624037403\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eProduct weight with unit packaging\u003c\/td\u003e\n\u003ctd\u003e4.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eBatteries included\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003ePackaging status\u003c\/td\u003e\n\u003ctd\u003eoriginal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eCertificates of conformity\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"elektromax_me","offers":[{"title":"Default Title","offer_id":45966527529020,"sku":"13231191596","price":3813.54,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0618\/2161\/6188\/files\/SONEL-MPI-540-PV-Start-Multifunction-Installation-Parameter-Meter.jpg?v=1786202305","url":"https:\/\/market365.lt\/products\/multifunkcinis-instaliaciju-parametru-matuoklis-sonel-mpi-540-pv-start","provider":"Market365","version":"1.0","type":"link"}