{"product_id":"dyzelinis-generatorius-machtmann-18000wd-18-kva-400v-trifazis","title":"Dyzelinis generatorius Machtmann 18000WD, 18 kVA, 400V, trifazis","description":"\u003ch2\u003eTrumpai apie prekę\u003c\/h2\u003e\u003cp\u003ePrekė: Dyzelinis generatorius Machtmann 18000WD, 18 kVA, 400V, trifazis. Kategorija: Elektros generatoriai.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGamintojas:\u003c\/strong\u003e Machtmann\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModelis:\u003c\/strong\u003e MN18000WD-ATS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eĮtampa:\u003c\/strong\u003e 400 V\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eMACHTMANN MN18000WD-ATS is a three-phase power generator designed for emergency power supply and operation in places without access to the power grid. The generator provides a voltage of 400 V for three-phase receivers and 230 V for single-phase devices.\u003c\/p\u003e\u003cp\u003eThe rated power of the generator is 13 kW, while the maximum power reaches 14 kW. With a power factor of cos φ 0,8, the maximum power of 14 kW corresponds to 17,5 kVA, which is why the model is commercially offered as an 18 kVA class unit.\u003c\/p\u003e\u003cp\u003eThe DualPower function allows you to switch the unit to a 230 V reinforced single-phase power supply mode. The solution increases the usability of the device when it is required to power more powerful single-phase receivers, and not just evenly distributed three-phase devices.\u003c\/p\u003e\u003cp\u003eThe team drives a 2V95 two-cylinder diesel engine in a V system. The unit is air-cooled, has an electric start and works with the SmartGen digital control panel. The closed housing reduces noise levels and protects the motor, generator and electrical systems from accidental damage.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003erated power of the generator 13 kW,\u003c\/li\u003e\n\u003cli\u003emaximum power 14 kW \/ 17,5 kVA,\u003c\/li\u003e\n\u003cli\u003ecommercial power class 18 kVA,\u003c\/li\u003e\n\u003cli\u003eoutput voltage 230\/400 V,\u003c\/li\u003e\n\u003cli\u003efrequency 50 Hz,\u003c\/li\u003e\n\u003cli\u003eDualPower function,\u003c\/li\u003e\n\u003cli\u003epossibility of reinforced single-phase power supply 230 V,\u003c\/li\u003e\n\u003cli\u003etwo-cylinder diesel engine 2V95,\u003c\/li\u003e\n\u003cli\u003esystem of cylinders type V,\u003c\/li\u003e\n\u003cli\u003efour-stroke OHV design,\u003c\/li\u003e\n\u003cli\u003eengine power about 26 hp,\u003c\/li\u003e\n\u003cli\u003eair cooling,\u003c\/li\u003e\n\u003cli\u003eelectric start-up E-START,\u003c\/li\u003e\n\u003cli\u003e12 V starter battery,\u003c\/li\u003e\n\u003cli\u003eSmartGen digital control panel,\u003c\/li\u003e\n\u003cli\u003epreparation for cooperation with ATS\/SZR,\u003c\/li\u003e\n\u003cli\u003eautomatic AVR voltage stabilization,\u003c\/li\u003e\n\u003cli\u003egenerator with winding made of 100% copper,\u003c\/li\u003e\n\u003cli\u003ethree-phase socket 400 V \/ 32 A,\u003c\/li\u003e\n\u003cli\u003esingle-phase socket 230 V \/ 32 A,\u003c\/li\u003e\n\u003cli\u003esingle-phase socket 230 V \/ 16 A,\u003c\/li\u003e\n\u003cli\u003e12V\/8A DC output,\u003c\/li\u003e\n\u003cli\u003ecircuit breakers and circuit protection,\u003c\/li\u003e\n\u003cli\u003efuel tank with a capacity of 30 l,\u003c\/li\u003e\n\u003cli\u003efuel level indicator,\u003c\/li\u003e\n\u003cli\u003eclosed silencing housing,\u003c\/li\u003e\n\u003cli\u003eweight of about 320 kg,\u003c\/li\u003e\n\u003cli\u003ecompact dimensions 1240 × 672 × 740 mm.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe rated power of the unit is 13 kW. This is the basic power level designed to regularly power receivers while maintaining appropriate cooling conditions and proper operation of the device.\u003c\/p\u003e\u003cp\u003eThe maximum power is 14 kW and is a short-term reserve available when taking over the load or starting selected devices. The unit should not be loaded with full maximum power for a long time.\u003c\/p\u003e\u003cp\u003eWith a power factor of cos φ 0,8, the parameters correspond approximately to:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003erated power: 13 kW \/ 16,25 kVA,\u003c\/li\u003e\n\u003cli\u003eMaximum power: 14 kW \/ 17,5 kVA.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe term ‘18 kVA’ used in the product name is the rounded trade name of the power class of the device.\u003c\/p\u003e\u003cp\u003eWhen selecting an aggregate, account should be taken of:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eactive and apparent power of receivers,\u003c\/li\u003e\n\u003cli\u003epower factor of equipment,\u003c\/li\u003e\n\u003cli\u003estarting currents of electric motors,\u003c\/li\u003e\n\u003cli\u003emethod of starting pumps and compressors,\u003c\/li\u003e\n\u003cli\u003eoccurrence of inverters or softstarts,\u003c\/li\u003e\n\u003cli\u003easymmetry of phase load,\u003c\/li\u003e\n\u003cli\u003epossibility of simultaneous operation of receivers,\u003c\/li\u003e\n\u003cli\u003econsumable stock required.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eWith a rated power of 13 kW, a voltage of 400 V and a power factor of cos φ 0,8, the calculated three-phase current is about 23,5 A:\u003c\/p\u003e\u003cp\u003e\u003cb\u003e13 000 IN ÷ (√3 × 400 V × 0,8) ≈ 23,5 A\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eFor a maximum power of 14 kW, the calculated current is about 25,3 A.\u003c\/p\u003e\u003cp\u003eThe 400 V \/ 32 A socket used has sufficient current capacity to use the declared power of the unit, provided that the load is properly distributed, the correct power factor of the receivers and the parameters provided by the manufacturer are maintained.\u003c\/p\u003e\u003cp\u003eMACHTMANN MN18000WD-ATS has a DualPower function, allowing you to switch the way the generator works and increase the power supply capabilities of single-phase receivers.\u003c\/p\u003e\u003cp\u003eIn a typical three-phase aggregate, the power available on a single 230 V phase is much less than the total generator power. DualPower allows you to use most of the potential of the unit at a single-phase output.\u003c\/p\u003e\u003cp\u003eThe solution is particularly useful during power supply:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003epower tools 230 V,\u003c\/li\u003e\n\u003cli\u003eheating devices,\u003c\/li\u003e\n\u003cli\u003esingle-phase pumps,\u003c\/li\u003e\n\u003cli\u003ecompressors,\u003c\/li\u003e\n\u003cli\u003erefrigeration equipment,\u003c\/li\u003e\n\u003cli\u003eworkshop equipment,\u003c\/li\u003e\n\u003cli\u003eprepared house circuits,\u003c\/li\u003e\n\u003cli\u003ecatering equipment,\u003c\/li\u003e\n\u003cli\u003eequipment used on construction sites.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe maximum power received by a single socket remains limited by its rated current. The 230 V \/ 32 A socket allows you to theoretically receive about 7,36 kVA, while the 230 V \/ 16 A socket about 3,68 kVA.\u003c\/p\u003e\u003cp\u003eSwitching between three-phase mode and DualPower should be done according to the instructions of the device, preferably without a connected load.\u003c\/p\u003e\u003cp\u003eThe heart of the unit is a four-stroke, two-cylinder 2V95 diesel engine. The cylinders are set in a V system, which allows you to obtain a compact unit design while maintaining the power appropriate for the generator of this class.\u003c\/p\u003e\u003cp\u003eThe declared engine power is about 26 hp. The unit uses diesel and has been adapted to drive a generator in a transport aggregate.\u003c\/p\u003e\u003cp\u003eThe two-cylinder design provides a more even operation than the single-cylinder diesel engines used in smaller units. The motor has an electric starter, thanks to which the start-up is carried out using a ignition and a control panel.\u003c\/p\u003e\u003cp\u003eThe 2V95 engine is air cooled. The system uses a fan that forces air flow around the components of the drive unit.\u003c\/p\u003e\u003cp\u003eAir cooling simplifies the design of the unit because the unit does not require a radiator, liquid pump, pipes or periodic replacement of coolant.\u003c\/p\u003e\u003cp\u003eDuring operation, however, it is necessary to ensure free air flow through the housing. Not allowed:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ecover ventilation openings,\u003c\/li\u003e\n\u003cli\u003eset the working unit directly against the wall,\u003c\/li\u003e\n\u003cli\u003eallow hot air to be sucked back in,\u003c\/li\u003e\n\u003cli\u003euse the device in a closed, non-ventilated room.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe unit should work outside, in a place protected against the accumulation of exhaust gases.\u003c\/p\u003e\u003cp\u003eMACHTMANN MN18000WD-ATS has an electric starting system. Starting the engine is carried out using a starter and a 12 V battery.\u003c\/p\u003e\u003cp\u003eThe kit is offered with a 12V\/30Ah starter battery. In the emergency installation, you should regularly check:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003estate of charge of the battery,\u003c\/li\u003e\n\u003cli\u003echarging voltage,\u003c\/li\u003e\n\u003cli\u003ecleanliness of terminals,\u003c\/li\u003e\n\u003cli\u003econnections of wires,\u003c\/li\u003e\n\u003cli\u003ethe action of the starter,\u003c\/li\u003e\n\u003cli\u003efuel and oil levels,\u003c\/li\u003e\n\u003cli\u003ereadiness of the control system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eLong-term leaving the unit without starting can lead to battery discharge. The device should be periodically tested under load.\u003c\/p\u003e\u003cp\u003eThe unit has a diesel tank with a capacity of 30 l and a fuel level indicator. This allows you to control the fuel supply without opening the tank.\u003c\/p\u003e\u003cp\u003eThere are two different combustion values in current commercial materials:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eabout 2,8 l\/h as average consumption,\u003c\/li\u003e\n\u003cli\u003eabout 1,1 l\/h at full load in the descriptive part.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFor a unit of this class, a value of about 2,8 l\/h is more realistic, but the actual combustion will depend on the load, operating mode, temperature, filter status and characteristics of the powered devices. The discrepancy is described in detail in the comments before publication.\u003c\/p\u003e\u003cp\u003eWith an average consumption of about 2,8 l\/h, the theoretical working time on a 30-liter tank is about 10 hours. Actual time will depend on the useful capacity of the tank and the load level.\u003c\/p\u003e\u003cp\u003eThe generator has a winding made of 100% copper. Copper provides good electrical conductivity, adequate thermal resistance and proper operating conditions of the generator under load.\u003c\/p\u003e\u003cp\u003eThe generator produces:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ethree-phase voltage 400 V,\u003c\/li\u003e\n\u003cli\u003esingle-phase voltage 230 V,\u003c\/li\u003e\n\u003cli\u003efrequency 50 Hz,\u003c\/li\u003e\n\u003cli\u003e12 V constant voltage.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe declared degree of protection of the generator is IP23. This designation refers to the protection of the electrical components of the generator, and not to the full water resistance of the entire unit.\u003c\/p\u003e\u003cp\u003eThe unit is equipped with an automatic AVR voltage regulator. The system controls the excitation of the generator and corrects the voltage during load changes.\u003c\/p\u003e\u003cp\u003eAVR improves power conditions, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eelectronics and household appliances,\u003c\/li\u003e\n\u003cli\u003erefrigerators and freezers,\u003c\/li\u003e\n\u003cli\u003ecentral heating furnaces,\u003c\/li\u003e\n\u003cli\u003epumps,\u003c\/li\u003e\n\u003cli\u003ecomputers,\u003c\/li\u003e\n\u003cli\u003epower tools,\u003c\/li\u003e\n\u003cli\u003emonitoring systems,\u003c\/li\u003e\n\u003cli\u003elighting,\u003c\/li\u003e\n\u003cli\u003eelectronic controllers.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAVR stabilizes the voltage, but does not turn the device into an inverter unit. The frequency of energy depends on the engine speed, and the quality of power supply can change during the rapid takeover of heavy load.\u003c\/p\u003e\u003cp\u003eMACHTMANN MN18000WD-ATS is equipped with a SmartGen digital control panel. The controller enables operation of the unit and monitoring of basic generator operating parameters.\u003c\/p\u003e\u003cp\u003eThe declared parameters of the panel include:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eNixie Tube LED Display,\u003c\/li\u003e\n\u003cli\u003eoperating panel made in PET technology,\u003c\/li\u003e\n\u003cli\u003eone digital input,\u003c\/li\u003e\n\u003cli\u003etwo relay outputs,\u003c\/li\u003e\n\u003cli\u003etwo analog inputs,\u003c\/li\u003e\n\u003cli\u003eoperation of alternator voltage from 30 to 360 V phase-neutral,\u003c\/li\u003e\n\u003cli\u003esupport for 50\/60 Hz frequency,\u003c\/li\u003e\n\u003cli\u003eprogramming via the LINK interface,\u003c\/li\u003e\n\u003cli\u003e9 to 18 V DC power supply,\u003c\/li\u003e\n\u003cli\u003eoperating temperature range from –25 to +70°C.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe exact symbol of the controller used is not indicated in the current product sheet.\u003c\/p\u003e\u003cp\u003eThe MN18000WD-ATS designation indicates the version prepared to cooperate with the ATS\/SZR automatic backup power supply system.\u003c\/p\u003e\u003cp\u003eThe ATS\/SZR is optionally available and can perform the following sequence:\u003c\/p\u003e\u003col\u003e\n\u003cli\u003econtrol of mains supply voltage,\u003c\/li\u003e\n\u003cli\u003edetection of decay or incorrect network parameters,\u003c\/li\u003e\n\u003cli\u003etransmission of the start-up signal to the unit,\u003c\/li\u003e\n\u003cli\u003eengine start-up,\u003c\/li\u003e\n\u003cli\u003econtrol of generator parameters,\u003c\/li\u003e\n\u003cli\u003eswitching the installation to power from the aggregate,\u003c\/li\u003e\n\u003cli\u003emonitoring the return of mains voltage,\u003c\/li\u003e\n\u003cli\u003eswitching receivers back to the network,\u003c\/li\u003e\n\u003cli\u003estop the aggregate after the end of the work cycle.\u003c\/li\u003e\n\u003c\/ol\u003e\u003cp\u003eThe aggregate panel includes:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e1 socket 230 V \/ 16 A,\u003c\/li\u003e\n\u003cli\u003e1 socket 230 V \/ 32 A,\u003c\/li\u003e\n\u003cli\u003e1 socket 400 V \/ 32 A,\u003c\/li\u003e\n\u003cli\u003e1 output 12V\/8A with rectifier function,\u003c\/li\u003e\n\u003cli\u003ethermal protection of the 12 V circuit,\u003c\/li\u003e\n\u003cli\u003eignition switch,\u003c\/li\u003e\n\u003cli\u003eprotection of circuits,\u003c\/li\u003e\n\u003cli\u003evoltage indicator.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe 400 V \/ 32 A socket allows you to theoretically receive:\u003c\/p\u003e\u003cp\u003e\u003cb\u003e√3 × 400 V × 32 A ≈ 22,2 kVA\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eIts load capacity is therefore higher than the maximum aggregate power of 17,5 kVA. However, the full use of power remains dependent on the uniform phase load and characteristics of the connected receivers.\u003c\/p\u003e\u003cp\u003eThe motor, generator and electrical systems were placed in a closed silencing housing. The design reduces noise emissions and protects the device components from accidental contact and damage.\u003c\/p\u003e\u003cp\u003eThe declared acoustic parameters are:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003esound pressure level LpA: about 75,1 dB(A),\u003c\/li\u003e\n\u003cli\u003eLwA sound power level: about 97 dB(A).\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe housing should not be referred to as completely waterproof. During outdoor use, the device should be protected from intense rainfall, flooding and water accumulation, while maintaining free ventilation.\u003c\/p\u003e\u003cp\u003eThe dimensions of the unit are approximately:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003elength: 1240 mm,\u003c\/li\u003e\n\u003cli\u003ewidth: 672 mm,\u003c\/li\u003e\n\u003cli\u003eHeight: 740 mm.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eThe weight of the unit is about 320 kg.\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eDue to the weight of the device, it is not an aggregate designed to be manually carried by one or two people. Transportation should be carried out using appropriate equipment, using the provided points or transport hook.\u003c\/p\u003e\u003cp\u003eThe set includes:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003egenerator set,\u003c\/li\u003e\n\u003cli\u003e12 V \/ 30 Ah battery,\u003c\/li\u003e\n\u003cli\u003ebattery mounting kit,\u003c\/li\u003e\n\u003cli\u003eeye wrench,\u003c\/li\u003e\n\u003cli\u003etransport hook.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eParameter:\u003c\/b\u003e Value\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eManufacturer of the unit:\u003c\/b\u003e MACHTMANN\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eModel:\u003c\/b\u003e MN18000WD-ATS\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eProduct code:\u003c\/b\u003e MN-18000WD-ATS\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e EAN code:\u003c\/b\u003e 5905954801503\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eType:\u003c\/b\u003e Mobile generator set\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eType:\u003c\/b\u003e Three-phase with DualPower\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eRated generator power:\u003c\/b\u003e 13 kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMaximum generator power:\u003c\/b\u003e 14 kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMaximum apparent power:\u003c\/b\u003e 17,5 kVA\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCommercial power class:\u003c\/b\u003e 18 kVA\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eVoltage:\u003c\/b\u003e 230\/400 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eFrequency:\u003c\/b\u003e 50 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePower factor at conversion:\u003c\/b\u003e cos φ 0,8\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eComputational current for 13 kW:\u003c\/b\u003e Approx. 23,5 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eComputational current for 14 kW:\u003c\/b\u003e Approx. 25,3 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDualPower function:\u003c\/b\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eFuel:\u003c\/b\u003e Diesel\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e Fuel tank capacity:\u003c\/b\u003e 30 l\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDeclared average combustion:\u003c\/b\u003e About 2,8 l\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eFuel level indicator:\u003c\/b\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eEngine model:\u003c\/b\u003e 2V95\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eEngine type:\u003c\/b\u003e Four-stroke Diesel OHV\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCylinder system:\u003c\/b\u003e 2 cylinders in V system\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eEngine power:\u003c\/b\u003e About 26 HP\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCooling:\u003c\/b\u003e Air\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eStart:\u003c\/b\u003e Electric E-START\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eBattery:\u003c\/b\u003e 12 V \/ 30 Ah\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eController:\u003c\/b\u003e SmartGen digital panel\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCurrent:\u003c\/b\u003e With copper winding\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCurve material:\u003c\/b\u003e 100% copper\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eVoltage stabilization:\u003c\/b\u003e AVR\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDegree of protection of the generator:\u003c\/b\u003e IP23\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eTS\/SZR automation:\u003c\/b\u003e Version prepared for cooperation\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e230 V sockets:\u003c\/b\u003e 1 × 16 A, 1 × 32 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e400 V socket:\u003c\/b\u003e 1 × 32 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDirect current output:\u003c\/b\u003e 12 V \/ 8 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eVoltmeter:\u003c\/b\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eHousing:\u003c\/b\u003e Closed, calming\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eLpA sound pressure level:\u003c\/b\u003e Approx. 75,1 dB(A)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eLwA sound power level:\u003c\/b\u003e About 97 dB(A)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDimensions:\u003c\/b\u003e 1240 × 672 × 740 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eWeight:\u003c\/b\u003e About 320 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eTransport:\u003c\/b\u003e Hook and transport points\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eParameters are compiled based on the current product sheets of the MN18000WD-ATS model and EAN code 5905954801503.\u003c\/p\u003e\u003cp\u003eMACHTMANN MN18000WD-ATS will work as a primary or emergency power source for:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003esingle-family houses,\u003c\/li\u003e\n\u003cli\u003eagricultural holdings,\u003c\/li\u003e\n\u003cli\u003eworkshops,\u003c\/li\u003e\n\u003cli\u003ecar services,\u003c\/li\u003e\n\u003cli\u003esmall production facilities,\u003c\/li\u003e\n\u003cli\u003eshops and service premises,\u003c\/li\u003e\n\u003cli\u003ecatering facilities,\u003c\/li\u003e\n\u003cli\u003ewarehouses,\u003c\/li\u003e\n\u003cli\u003econstruction sites,\u003c\/li\u003e\n\u003cli\u003etechnical facilities,\u003c\/li\u003e\n\u003cli\u003epumps and hydrophors,\u003c\/li\u003e\n\u003cli\u003ecentral heating installations,\u003c\/li\u003e\n\u003cli\u003eboiler rooms,\u003c\/li\u003e\n\u003cli\u003erefrigerators and freezers,\u003c\/li\u003e\n\u003cli\u003erefrigeration equipment,\u003c\/li\u003e\n\u003cli\u003epower tools,\u003c\/li\u003e\n\u003cli\u003ecompressors,\u003c\/li\u003e\n\u003cli\u003elighting,\u003c\/li\u003e\n\u003cli\u003ealarm and monitoring systems,\u003c\/li\u003e\n\u003cli\u003esingle-phase devices 230 V,\u003c\/li\u003e\n\u003cli\u003e400 V three-phase machines.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eBefore connecting a pump, compressor, welding machine or electric motor, it is necessary to take into account its inrush current and leave an adequate supply of power.\u003c\/p\u003e\u003ch2\u003eIs the unit 18 kVA or 14 kW?\u003c\/h2\u003e\u003cp\u003eBoth values describe the same class of aggregate, but in different units. The maximum active power is 14 kW, which at the power factor cos φ 0,8 corresponds to 17,5 kVA. In the trade name, the value was rounded to 18 kVA.\u003c\/p\u003e\u003ch2\u003eWhat is the rated power?\u003c\/h2\u003e\u003cp\u003eThe rated power of the generator is 13 kW. The power of 14 kW is the maximum power, designed for short-term use.\u003c\/p\u003e\u003ch2\u003eHow much does MACHTMANN MN18000WD-ATS weigh?\u003c\/h2\u003e\u003cp\u003eThe weight of the device is about \u003cb\u003e320 kg\u003c\/b\u003e. Appropriate equipment and intended transport points shall be used for transport.\u003c\/p\u003e\u003ch2\u003eDoes the unit provide 230 V and 400 V voltage?\u003c\/h2\u003e\u003cp\u003eYes. The device has two 230 V sockets and one three-phase 400 V socket.\u003c\/p\u003e\u003ch2\u003eWhat is DualPower?\u003c\/h2\u003e\u003cp\u003eDualPower allows you to switch the generator into a single-phase enhanced power supply mode, so that most of the generator’s capabilities can be used by 230 V receivers.\u003c\/p\u003e\u003ch2\u003eCan the full power be received through the 400V\/32A socket?\u003c\/h2\u003e\u003cp\u003eYes, the load capacity of the 400 V \/ 32 A socket is sufficient for an aggregate with a maximum power of 17,5 kVA. However, the phase load should be maintained evenly and the characteristics of the receivers taken into account.\u003c\/p\u003e\u003ch2\u003eDoes the unit start automatically?\u003c\/h2\u003e\u003cp\u003eThe model is ATS marked and is designed to work with ATS\/SZR automation. It shall be confirmed whether the specific set includes a complete external switching switch.\u003c\/p\u003e\u003ch2\u003eDoes the unit have voltage stabilization?\u003c\/h2\u003e\u003cp\u003eYes. The generator works with an automatic AVR voltage regulator.\u003c\/p\u003e\u003ch2\u003eIs the generator inverter?\u003c\/h2\u003e\u003cp\u003eNo. It is a classic generator set with a copper generator and AVR voltage regulator.\u003c\/p\u003e\u003ch2\u003eIs the engine cooled by liquid?\u003c\/h2\u003e\u003cp\u003eNo. The 2V95 two-cylinder engine is air-cooled.\u003c\/p\u003e\u003ch2\u003eHow much fuel does the tank hold?\u003c\/h2\u003e\u003cp\u003eThe tank holds 30 l of diesel fuel.\u003c\/p\u003e\u003ch2\u003eCan the device work in a closed room?\u003c\/h2\u003e\u003cp\u003eNo. The unit emits toxic exhaust gases and should work outside. Use in a specially prepared room requires the design of ventilation and tight exhaust gas drainage by authorized specialists.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eGroup\u003c\/th\u003e\n\u003cth\u003eName\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003enew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eInvoice\u003c\/td\u003e\n\u003ctd\u003eWith VAT invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eMachtmann\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMN18000WD-ATS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eKind\u003c\/td\u003e\n\u003ctd\u003eportable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eGenerator type\u003c\/td\u003e\n\u003ctd\u003ethree-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eEngine\u003c\/td\u003e\n\u003ctd\u003e4-stroke\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eStartup\u003c\/td\u003e\n\u003ctd\u003eelectric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eMaximum power\u003c\/td\u003e\n\u003ctd\u003e14000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eNominal power of the alternator\u003c\/td\u003e\n\u003ctd\u003e13000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eEngine power\u003c\/td\u003e\n\u003ctd\u003e26 KM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eGasoline tank capacity\u003c\/td\u003e\n\u003ctd\u003e30 l\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eDevice weight\u003c\/td\u003e\n\u003ctd\u003e320 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eFuel type\u003c\/td\u003e\n\u003ctd\u003ediesel fuel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eProduct height\u003c\/td\u003e\n\u003ctd\u003e90 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eProduct width\u003c\/td\u003e\n\u003ctd\u003e120 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eProduct depth\u003c\/td\u003e\n\u003ctd\u003e65 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eAverage combustion\u003c\/td\u003e\n\u003ctd\u003e2.8 l\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eNumber of 1-phase outlets\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eNumber of 3-phase outlets\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003e400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eManufacturer code\u003c\/td\u003e\n\u003ctd\u003eMN-18000WD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eAdditional information\u003c\/td\u003e\n\u003ctd\u003evoltage regulation (AVR),12 V outlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Bajdrew","offers":[{"title":"Default Title","offer_id":46066316967996,"sku":"18361904626","price":4729.32,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0618\/2161\/6188\/files\/Generator-set-Diesel-Machtmann-18000WD-400V-18-kVA-Three-phase.jpg?v=1787859380","url":"https:\/\/market365.lt\/products\/dyzelinis-generatorius-machtmann-18000wd-18-kva-400v-trifazis","provider":"Market365","version":"1.0","type":"link"}