Piegādes termiņš katrai precei ir norādīts pie cenas bloka.
Piegāde visā Lietuvā: bez maksas.
Trumpai apie prekę
Prekė: Gliukozės matavimo juostelės Sinocare AQ PRO, 100 vnt. (be matuoklio). Kategorija: Gliukozės matuokliai.
- Gamintojas: Sinocare
- Modelis: Safe AQ Pro I
Blood Glucose Reactive Strips: codefree strips x 100 & Painless lancets x 100 for Safe AQ Pro I. Safe AQ Pro I blood glucose test strips are only compatible with Safe AQ Pro I blood glucose meter and are not compatible with other products.
High cost performance: affordable for daily use. Storage and shelf life of test strips!
Note 1 - Shelf life: 24 months if stored at 33.8℉ to 86℉ (1℃-30℃) unopened.
Note 2 - Ambient humidity has a moderate effect, the measured value will fluctuate by 15%. Therefore, try to store the test strip in an environment with <80% humidity to improve accuracy.
Accurate and easy to use: Sinocare Safe AQ Pro I test strips require no code, only 5s test, 1 microliter blood sample. Using silver composite electrode technology. The five-electrode system can guarantee measurement accuracy under special circumstances. HCT (10% - 70%) can meet the needs of more special people. Standard measurement results mg/ dL.
Date guaranteed freshness: Sinocare Safe AQ Pro I test strips without coding are fresh and have a guaranteed expiration date of 1 2 to 24 months.(6 months from the first time bottle opening time.)
Valuable gifts for family and friends: Help you monitor the glycemic index of your friends and family to help them stay healthy. This is a sweet and valuable gift for parents, grandparents, relatives, children and friends.
Sinocare Safe AQ Pro I test strips were another technical breakthrough.
1) A five-electrode system is used in the blood collection area.
2) On the back of the test strips, 8-electrode technology was used for automatic coding and additional calibration.
3) The “hematocrit correction” technology on carbon test strips has been implemented.
4) FAD-GDH enzymatic reaction technology has been adopted and better resistance to interference can be achieved.
Sinocare Safe AQ Pro I blood glucose test strips are only compatible with Sinocare Safe AQ Pro I blood glucose meters; other types of meters are not applicable.
When opening for the first time, record the discard date (6 months after opening) on the bottle label.
Use the test strip according to the expiration date of the vial, and discard the remaining test strips after the expiration date.
Sticking of the test strip is a normal phenomenon and does not affect normal use.
After taking the strip, immediately cap the bottle to prevent loss of effectiveness.
Insert the electrode port of the strips into the meter.
Complete the process of sucking blood in one go. If the blood does not fill in one time, do not add blood samples, but simply replace them with new test strips.
It is recommended to use up the test strip within 3 minutes, otherwise the meter will turn off.
When the meter starts measuring, do not move the test strip or press any buttons on the meter.
Never reuse a test strip soiled with blood.
Specifications
| Group | Name | Value |
|---|---|---|
| Parametry | Condition | new |
| Parametry | Invoice | With VAT invoice |
| Parametry | Product weight with unit packaging | 0.1 kg |
| Parametry | Medical device | yes |
| Parametry | Medical device type | medical device or in-vitro diagnostic medical device |
| Parametry | Manufacturer of a medical device | Sinocare |
| Parametry | Authorized representative | Shanghai International Holding Corp. GmbH |
| Parametry | Medical device class | IIa |
| Parametry | Notified body number | 100 |
| Parametry | Measurement | glucose |
| Parametry | Brand | Sinocare |
| Parametry | Manufacturer code | 14101226-Allegro |
| Parametry | Model | Safe AQ Pro I |
| Parametry | Blood sample volume | 0.6 μl |
| Parametry | Measurement time | 5 s |
| Parametry | Average measurement | not specified |
| Parametry | Number of memorized measurements | 500 |
| Parametry | Number of strips | 100 |
| Parametry | Number of lancets | 100 |
| Parametry | EAN (GTIN) | 0756740875506 |
| Parametry | Packaging status | original |
| Parametry | Batteries included | no |
| Parametry | Certificates of conformity | CE |
| Parametry | Set components | lancets,stripes |