Piegādes termiņš katrai precei ir norādīts pie cenas bloka.
Piegāde visā Lietuvā: bez maksas.
Trumpai apie prekę
Prekė: Gliukometras Sinocare SAFE AQ Pro su 50 juostelių ir 50 lancetų (mg/dl). Kategorija: Gliukozės matuokliai.
- Gamintojas: Sinocare
- Modelis: AQ pro I
Sinocare Safe AQ Pro I glucose meter
1、Intelligent assessment of blood sugar level, red, yellow and green color indicator.
2、When your blood glucose level is ≥ 13.9 mmol/L, the Safe AQ Pro I glucose meter notifies you that ketone bodies have been detected in your blood.
3、Pre-meal, post-meal and random blood glucose icons can be displayed.
4、The large LCD screen can make it easy to read.
5、Capacity of 500, you can get easy blood sugar monitoring.
6、Automatic siphon
7、Blood collection can be completed by gently touching the blood sample, the operation becomes easier.
8、Silver composite electrode
9、The conductivity is more than 10 times higher than the carbon test strip, and the test strip can be more stable and resistant to interference.
Value in 5 seconds
10、A blood sample of 1 microliter and a value in 5 seconds enable faster measurement.
Using FAD-GDH technology: only works on glucose, it is not affected by xylose, maltose, oxygen, light intensity, etc. It has good anti-interference ability, and the measured value is more reliable
Intelligent blood glucose determination: when the value is above 250 or below 70 mg/dl, the indication is red, indicates risk; when the value is between 70 and 126 mg/dl, the indication is green, the blood glucose level is normal; when it is between 126 and 250 mg/dl, the indication is yellow
Large storage capacity: the new AQ Pro can store 500 sets of test data and display global averages of pre-meal and post-meal blood glucose levels for 7/14/30/90 days. In this way, users can better monitor and record daily changes in blood glucose levels.
The Sinocare Safe AQ Pro I test strips were another technical breakthrough.
A five-electrode system was used in the blood collection area.
On the back of the test strips, 8-electrode technology was used to enable automatic coding and secondary calibration.
The “hematocrit correction” technology on carbon test strips was implemented.
FAD-GDH enzymatic reaction technology has been used, so better resistance to interference can be achieved.
Sinocare Safe AQ Pro I blood glucose meter can only be used with Sinocare Safe AQ Pro I blood glucose test strips. Test strips of other types cannot be used.
After inserting the batteries, the meter will enter the date and time setting mode. If you do not need to change them, press the right button several times until it turns off.
When you open it for the first time, write down the discard date (6 months after opening) on the bottle label. Discard any test strips remaining after the discard date.
Use cosmetic pads containing 75% alcohol to disinfect. Do not use iodine or disinfectants.
Please do not re-sterilize, wait for the alcohol to evaporate.
It is necessary to complete the blood suction process in one go. If the blood is not completed once, please do not add blood samples, only replace them with new test strips.
When the meter starts measuring, do not move the test strip or press any buttons on the meter.
Results from alternative sites do not reflect your current blood glucose level.
Adjust the depth of the pricker to the thickness of your skin.
Specifications
| Group | Name | Value |
|---|---|---|
| Parametry | Condition | new |
| Parametry | Invoice | With VAT invoice |
| Parametry | Product weight with unit packaging | 0.4 kg |
| Parametry | Medical device | yes |
| Parametry | Medical device type | medical device or in-vitro diagnostic medical device |
| Parametry | Manufacturer of a medical device | Sinocare.Inc |
| Parametry | Medical device class | IIa |
| Parametry | Measurement | glucose |
| Parametry | Brand | Sinocare |
| Parametry | Model | AQ pro I |
| Parametry | Blood sample volume | 1 μl |
| Parametry | Measurement time | 5 s |
| Parametry | Average measurement | from 14 days |
| Parametry | Glucose measurement range | 20–600 mg/dl |
| Parametry | Number of memorized measurements | 500 |
| Parametry | Number of strips | 50 |
| Parametry | Number of lancets | 50 |
| Parametry | Product width | 20 cm |
| Parametry | Product height | 17 cm |
| Parametry | Product depth | 7 cm |
| Parametry | Product weight | 450 g |
| Parametry | Power supply | batteries |
| Parametry | EAN (GTIN) | 10679065121967 |
| Parametry | Packaging status | original |
| Parametry | Batteries included | yes |
| Parametry | Certificates of conformity | WEEE |
| Parametry | Kind | Glucose Meter |
| Parametry | Additional features | automatic coding,automatic shutdown,blood sucking test strips,average value of measurement results |
| Parametry | Set components | batteries,case,lancets,injector,stripes |