{"product_id":"elektriniu-instaliaciju-parametru-matuoklis-sonel-mpi-520","title":"Elektrinių instaliacijų parametrų matuoklis SONEL MPI-520","description":"\u003ch2\u003eTrumpai apie prekę\u003c\/h2\u003e\u003cp\u003ePrekė: Elektrinių instaliacijų parametrų matuoklis SONEL MPI-520. Kategorija: Detektoriai.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGamintojas:\u003c\/strong\u003e Sonel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModelis:\u003c\/strong\u003e WMPLMPI520\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eElectrical Installation Parameter Meter\u003c\/h2\u003e\u003cp\u003e\u003cb\u003eSONEL MPI-520 - basic version\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eProfessional measurements within your budget? \u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eExplore the versatile Sonel MPI-520 meter!\u003c\/b\u003e This easy-to-use, yet advanced device is ideal for both d\u003cb\u003efor novice installers\u003c\/b\u003e and \u003cb\u003eexperienced specialists.\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eIt combines the \u003cb\u003efunctions of many devices\u003c\/b\u003e, enabling precise measurements of short-circuit loop impedance (also with RCD), ground resistance and residual current circuit breaker parameters (AC, A, B).\u003c\/p\u003e\u003cp\u003eThe rugged IP54 enclosure guarantees \u003cb\u003ereliability even in harsh environments\u003c\/b\u003e. Thanks to the memory of results and wireless data transmission, work becomes even more efficient.\u003c\/p\u003e\u003ch2\u003eThe set includes:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003e1 pcs. \u003c\/b\u003e Multifunctional \u003cb\u003emeasurement of parameters\u003c\/b\u003e of electrical installations \u003cb\u003eMPI-520\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pcs. \u003c\/b\u003e \u003cb\u003eAdapter\u003c\/b\u003e triggering measurement (UNI-Schuko plug) \u003cb\u003eWS-03\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pcs. \u003c\/b\u003e \u003cb\u003eCable\u003c\/b\u003e 1,2 m \u003cb\u003ered \u003c\/b\u003e1 kV (banana plugs) \u003cb\u003eWAPRZ1X2REBB\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pcs. \u003c\/b\u003e \u003cb\u003eCable\u003c\/b\u003e 1,2 m \u003cb\u003eblue\u003c\/b\u003e 1 kV (banana plugs) \u003cb\u003eWAPRZ1X2BUBB\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pcs. \u003c\/b\u003e \u003cb\u003eCable\u003c\/b\u003e 1,2 m \u003cb\u003eyellow \u003c\/b\u003e1 kV (banana plugs) \u003cb\u003eWAPRZ1X2YEBB\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pcs. \u003c\/b\u003e \u003cb\u003eCable\u003c\/b\u003e 15 m \u003cb\u003eblue \u003c\/b\u003efor measuring grounding on spool (banana plugs) \u003cb\u003eWAPRZ015BUBBSZ\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pcs. \u003c\/b\u003e \u003cb\u003eCable\u003c\/b\u003e 30 m \u003cb\u003ered\u003c\/b\u003e for measuring grounding on spool (banana plugs) \u003cb\u003eWAPRZ030REBBSZ\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pcs. \u003c\/b\u003e \u003cb\u003eProbe\u003c\/b\u003e blade \u003cb\u003ered \u003c\/b\u003e1 kV (banana socket) \u003cb\u003eWASONREOGB1\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pcs. \u003c\/b\u003e \u003cb\u003eProbe\u003c\/b\u003e blade \u003cb\u003eblue \u003c\/b\u003e1 kV (banana socket) \u003cb\u003eWASONBUOGB1\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pcs. \u003c\/b\u003e \u003cb\u003eProbe \u003c\/b\u003eblade \u003cb\u003eyellow \u003c\/b\u003e1 kV (banana socket) \u003cb\u003eWASONYEOGB1\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e2 pcs. \u003c\/b\u003e \u003cb\u003eProbe\u003c\/b\u003e ground 30 cm \u003cb\u003eWASONG30\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pcs. \u003c\/b\u003e \u003cb\u003eCrocodile\u003c\/b\u003e red 1 kV 20 A \u003cb\u003eK-02\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pcs. \u003c\/b\u003e \u003cb\u003eCrocodile\u003c\/b\u003e yellow 1 kV 20 A \u003cb\u003eK-02\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e4 pcs. \u003c\/b\u003e \u003cb\u003eBattery\u003c\/b\u003e alkaline LR14 (C) 1,5 V \u003cb\u003eWABATLR14\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pcs. \u003c\/b\u003e \u003cb\u003eContainer\u003c\/b\u003e simple battery operated \u003cb\u003eWAPOJ1\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pcs. \u003c\/b\u003e \u003cb\u003eL-2 case \u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pcs. \u003c\/b\u003e \u003cb\u003eSzelki\u003c\/b\u003e for meter set \u003cb\u003eWAPOZSZEKPL\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pcs. \u003c\/b\u003e \u003cb\u003eCable\u003c\/b\u003e USB \u003cb\u003eWAPRZUSB\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1 pcs. \u003c\/b\u003e \u003cb\u003eCalibration certificate \u003c\/b\u003e\u003cb\u003eWADOKCK\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eOperating Instructions\u003c\/b\u003e in Polish\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe calibration certificate is a document issued free of charge in the production process of the meter.\u003c\/p\u003e\u003cp\u003eIt confirms the conferral of metrological properties and maintaining measurement consistency.\u003c\/p\u003e\u003cp\u003eIn the calibration certificate under the date of issue of the document there is a dotted field: “Date of commissioning”. This is the field left for the instrument user in which the date of purchase should be entered.\u003c\/p\u003e\u003cp\u003eThe entered date of purchase can be used to determine the next calibration date based on the manufacturer’s recommendation below:\u003c\/p\u003e\u003cp\u003eSubsequent execution of the metrological confirmation (calibration) is recommended to be carried out within 12 months from the date of purchase, but no later than 24 months from the date of production \/ checking.\u003c\/p\u003e\u003cp\u003eAnother metrological inspection is carried out by the Research and Calibration Laboratory of Sonel S.A. companies, and the issued document is called - Calibration Certificate.\u003c\/p\u003e\u003ch2\u003eBasic advantages and functions\u003c\/h2\u003e\u003cp\u003e✔ \u003cb\u003eMeasuring versatility:\u003c\/b\u003e It enables all acceptance measurements of electrical installations in accordance with PN-EN 61557, combining the functions of many devices.\u003c\/p\u003e\u003cp\u003e✔ \u003cb\u003ePrecise short-circuit loop measurements:\u003c\/b\u003e Accurate short-circuit loop impedance measurement, also in circuits with RCD circuit breakers, with automatic short-circuit current calculation.\u003c\/p\u003e\u003cp\u003e✔ \u003cb\u003eComprehensive RCD test:\u003c\/b\u003e Testing the parameters of AC, A and B residual current circuit breakers, with measurement of current and operating time, as well as touch voltage.\u003c\/p\u003e\u003cp\u003e✔ \u003cb\u003eWide range of insulation resistance measurement:\u003c\/b\u003e Possibility to measure insulation resistance up to 3 GΩ at different measuring voltages (up to 1000 V), with automatic capacity discharge function.\u003c\/p\u003e\u003cp\u003e✔ \u003cb\u003eAccurate measurement of grounding and continuity:\u003c\/b\u003e Measurement of grounding resistance by 3-wire method and continuity of protective and compensatory connections with current ≥200 mA.\u003c\/p\u003e\u003cp\u003e✔ \u003cb\u003eSafety of use:\u003c\/b\u003e Checking the correctness of PE connection with a touch electrode, protection against voltage on the object, detection of L and N wire replacement.\u003c\/p\u003e\u003cp\u003e✔ \u003cb\u003eConvenience and automation of work:\u003c\/b\u003e Automatic RCD examination, the possibility of using adapters for sockets and testing the insulation of multicore wires, auto-calibration of measuring wires.\u003c\/p\u003e\u003cp\u003e✔ \u003cb\u003eAdditional functions:\u003c\/b\u003e Measurement of voltage and frequency of the network, indication of the order of phases, and with clamps - measurement of current, power and cosφ.\u003c\/p\u003e\u003cp\u003e✔ \u003cb\u003eMemory and data transmission:\u003c\/b\u003e Ability to save 990 results and wireless (Bluetooth) or wired (USB) transfer them to your computer.\u003c\/p\u003e\u003cp\u003e✔ \u003cb\u003eSturdy construction and compliance with standards:\u003c\/b\u003e Housing with IP54 protection, compliance with PN-EN 61557 and high measurement category (CAT IV 300 V, III 600 V), SEP recommendation.\u003c\/p\u003e\u003ch2\u003eSoftware to support the Sonel MPI-520 device\u003c\/h2\u003e\u003cp\u003e✔ \u003cb\u003eSONEL ELECTRICAL MEASUREMENTS 6\u003c\/b\u003e (not included)\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eHelps \u003cb\u003ecreate electrical measurement reports\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eSimplifies the documentation process\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eAutomates\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eTree structure\u003c\/b\u003e of the document\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003ePossibility to purchase the PE6 program at our other auctions!\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e✔ \u003cb\u003eSONEL READER - FREE\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eCollect historical data\u003c\/b\u003e and compare \u003cb\u003eit with current results\u003c\/b\u003e transferred from the meter's extensive memory.\u003c\/li\u003e\n\u003cli\u003eIt allows you \u003cb\u003eto transfer data to a computer\u003c\/b\u003e , \u003cb\u003esave it to popular\u003c\/b\u003e formats and print it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eTrack the progress\u003c\/b\u003e of insulation degradation\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePlan\u003c\/b\u003e renovation work.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eMeasurement functions:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eFault loop impedance:\u003c\/p\u003e\n\u003cp\u003eFault loop ZLoE ZL+ Z14: 0.13 ...1999 (acc. to IEC 61557), display range 0.00 ...1999, resolution from 0.01, accuracy (5% wm + 3 digits). ;\u003c\/p\u003e\n\u003cp\u003eZLOE fault loop in RCD mode: from 0.50 ...1999 (acc. to IEC 61557), display range 0.00 ...1999, resolution from 0.01, accuracy from (6% wm + 5 digits). ;\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasurements of RCD parameters:\u003c\/p\u003e\n\u003cp\u003eRCD tripping test and tripping time measurement (tA), measuring current 0.5, 1, 2, 5, In:;\u003c\/p\u003e\n\u003cp\u003eMeasurement of RCD tripping current IA, measuring current 0.2, 0.4, 0.6, 0.8, 1.0, 1.1, 1.2, 1.3, 1.4, 1.5, In:;\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding resistance:\u003c\/p\u003e\n\u003cp\u003e3-wire method: from 0.5 ...1.99 kΩ (acc. to IEC 61557-5), display range 0.00 ...1.99 kΩ, resolution from 0.01 , accuracy from (2% wm + 3 digits). ;\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInsulation resistance:\u003c\/p\u003e\n\u003cp\u003eMeasuring voltage 50 V: 50 kΩ. .250 M (according to IEC 61557-2), display range 0 k.. .250 M, resolution from 1 k, accuracy from (3% wm + 8 digits). ;\u003c\/p\u003e\n\u003cp\u003eMeasuring voltage 100 V: 100 kΩ. .500 M (according to IEC 61557-2), display range 0 k.. .500 M, resolution from 1 k, accuracy from (3% wm + 8 digits). ;\u003c\/p\u003e\n\u003cp\u003eMeasuring voltage 250 V: 250 kΩ. .999 M (according to IEC 61557-2), display range 0 k.. .999 M, resolution from 1 k, accuracy from (3% wm + 8 digits). ;\u003c\/p\u003e\n\u003cp\u003eMeasuring voltage 500 V: 500 kΩ. .2.00 G (according to IEC 61557-2), display range 0 k.. .2.00 G, resolution from 1 k, accuracy from (3% wm + 8 digits). ;\u003c\/p\u003e\n\u003cp\u003eMeasuring voltage 1000 V: 1000 kΩ. .3.00 G (according to IEC 61557-2), display range 0 k.. .3.00 G, resolution from 1 k, accuracy from (3% wm + 8 digits). ;\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance of protective and equipotential bonding conductors:\u003c\/p\u003e\n\u003cp\u003eMeasurement of continuity of protective and equipotential bonding with current 200 mA: 0.12 ...400 (acc. to IEC 61557-4), display range 0.00 ...400, resolution from 0.01, accuracy (2% wm + 3 digits). ;\u003c\/p\u003e\n\u003cp\u003eResistance measurement with low current: 0.0 ... 1999 , display range 0.0 ... 1999 , resolution from 0.1 , accuracy (3% wm + 3 digits). ;\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003ePhase sequence indication: positive, negative, ULL voltage: 95 V. .500 V (45 Hz...65 Hz).\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower measurement:\u003c\/p\u003e\n\u003cp\u003eApparent power (S): 0.0 VA.. .200,000 VA, resolution from 0.1 VA, accuracy from (7% wm + 3 digits). ;\u003c\/p\u003e\n\u003cp\u003eActive power (P): 0.0 W. .200,000 W, resolution from 0.1 W, accuracy from (7% wm + 3 digits). ;\u003c\/p\u003e\n\u003cp\u003eReactive power (Q): 0.0 var.. .200,000 var, resolution from 0.1 var. ;\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eOther technical data:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp\u003eMeasurement category according to PN-EN 61010: IV 300 V, III 600 V.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eDegree of protection: IP54.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eType of insulation according to PN-EN 61010-1 and IEC 61557: double.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eDimensions: 288 x 223 x 75 mm.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eMeter weight: approx. 2,2 kg.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eOperating temperature: 0...+50°C.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eStorage temperature: -20...+70°C.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eHumidity: 20...90%.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eNominal temperature: 232°C.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eReference humidity: 40%...60%.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eMemory of measurement results: 990 cells, 57 500 records.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eTransmission of results: USB 2.0, radio.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eQuality standard development, design and production: ISO 9001.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eThe product meets the requirements of EMC (emission for industrial environment) according to the following standards: PN-EN 61326-1, PN-EN 61326-2-2.\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCONSTRUCTION OF THE INSTALLATION PARAMETERS METER\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003e1- Charger socket and USB\u003c\/b\u003e under sliding flap\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e2- Measuring sockets \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e3- Clamp socket\u003c\/b\u003e measuring\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e4- Turning on and off\u003c\/b\u003e meter power\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e5- MENU-\u003c\/b\u003e selection of additional meter settings\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e6- Turn the backlight on and off\u003c\/b\u003e of the display\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e7- Rotary switch\u003c\/b\u003e functions\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e8 and 10- Ears for harness fastening \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e9- Display Operation Keys\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e11- Offset\/select \u003c\/b\u003eright\/left, up\/down\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e12- ESC\u003c\/b\u003e- return to previous screen, exit from function\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e13- Approval\u003c\/b\u003e of selection\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e14- Touch electrode\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e15- Starting the measurement procedure\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e16- Charger socket\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e17- USB port \u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eComparison of MPI measures\u003c\/h2\u003e\u003cp\u003e\u003cb\u003eSigns in Table \u003c\/b\u003e\u003c\/p\u003e\u003col\u003e\n\u003cli\u003e\u003cb\u003eMeasuring voltage [V]\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eMeasuring range \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003ePower supply\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eMemory (number of records)\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eMeasurement function of ground resistance\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eExpandable with lux meter probe\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch2\u003eSpecification\u003c\/h2\u003e\u003cp\u003eMarkings in the table:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cb\u003e1- Measuring range \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e2- Display range \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e3- Resolution\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e4- Accuracy \u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eA\u003c\/b\u003e- Grounding resistance\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cb\u003eA1\u003c\/b\u003e- 3-wire method\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eB\u003c\/b\u003e- Insulation resistance\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eB1- \u003c\/b\u003eMeasuring voltage 50 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eB2- \u003c\/b\u003eMeasuring voltage 100 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eB3- \u003c\/b\u003eMeasuring voltage 250 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eB4- \u003c\/b\u003eMeasuring voltage 500 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eB5- \u003c\/b\u003eMeasuring voltage 1000 V\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eC\u003c\/b\u003e- Resistance of protective and compensating conductors\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eC1\u003c\/b\u003e- Measurement of continuity of protective and compensatory connections with current ±200 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eC2\u003c\/b\u003e- Measurement of resistance with low current\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eD\u003c\/b\u003e- Indications of phase order\u003c\/p\u003e\u003cp\u003e\u003cb\u003eE\u003c\/b\u003e- Power measurement\u003c\/p\u003e\u003ch2\u003eSpecification\u003c\/h2\u003e\u003cp\u003eSymbols in the table:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cb\u003e1- Measurement range\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e2- Display range\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e3- Resolution\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e3- Accuracy\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eA-\u003c\/b\u003e Fault loop impedance\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eA1-\u003c\/b\u003e Short circuit loop ZL-PE, ZL-N, ZL-L\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eA2-\u003c\/b\u003e ZL-PE short circuit loop in RCD mode\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eB-\u003c\/b\u003e Measurements of RCD parameters, RCD tripping test and measurement of tripping time tA measuring current 0.5 IΔn, 1 IΔn, 2 IΔn, 5 IΔn\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eB1\u003c\/b\u003e - RCD of general type and short-time delay\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eB2\u003c\/b\u003e - Selective RCD\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eC\u003c\/b\u003e - Measurement of RCD tripping current IA measuring current 0.2 IΔn…2.0 IΔn\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eC1\u003c\/b\u003e - for sinusoidal differential current (AC type)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eC2\u003c\/b\u003e - for 1-way differential current and 1-way differential current with 6 mA DC bias (type A)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eC3\u003c\/b\u003e - for direct differential current (type B)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eGroup\u003c\/th\u003e\n\u003cth\u003eName\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003enew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eInvoice\u003c\/td\u003e\n\u003ctd\u003eWith VAT invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSonel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eKind\u003c\/td\u003e\n\u003ctd\u003evoltage detector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003ebattery and mains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eManufacturer code\u003c\/td\u003e\n\u003ctd\u003eWMPLMPI520\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eEAN (GTIN)\u003c\/td\u003e\n\u003ctd\u003e5907624013148\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eProduct weight with unit packaging\u003c\/td\u003e\n\u003ctd\u003e6.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eBatteries included\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003ePackaging status\u003c\/td\u003e\n\u003ctd\u003eoriginal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eCertificates of conformity\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"elektromax_me","offers":[{"title":"Default Title","offer_id":45961225895996,"sku":"11873847784","price":1927.81,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0618\/2161\/6188\/files\/SONEL-MPI-520-Multifunctional-Electrical-Installation-Parameter-Meter.jpg?v=1786106775","url":"https:\/\/market365.lt\/lv\/products\/elektriniu-instaliaciju-parametru-matuoklis-sonel-mpi-520","provider":"Market365","version":"1.0","type":"link"}