Lieferzeit in ganz Litauen: 5-10 Werktage
Lieferpreis an die angegebene Adresse: 3 Euro
Trumpai apie prekę
Prekė: Vandens UV sterilizatorius TMA D10 (3,90 m3/h) baktericidinė lempa. Kategorija: Vandens filtrai ir minkštikliai.
- Gamintojas: TMA
- Modelis: D10 304
- Talpa: 0 l
⭐ UV STERILIZER FOR WATER TMA D10 – CAPACITY 3,90 m³/h
✅ The UV TMA D10 sterilizer is a powerful device designed for disinfection of water in small and medium-sized installations. It will work well in single-family houses equipped with 2 to 3 bathrooms, small holiday homes, apartments, offices and small commercial facilities.
✅ The device uses UV radiation with a wavelength of 254 nm, which neutralizes bacteria, viruses and other microorganisms found in flowing water. The process takes place without the use of chemicals, so it does not change the taste or smell of water.
⭐ The most important advantages of the sterilizer
✅ Disinfection without chemicals – UV radiation neutralizes microorganisms without the need to dispense chlorine or other preparations.
✅ Nominal flow rate 3,90 m³/h – the device is suitable for small and medium-sized domestic and utility installations.
✅ UV radiator with a power of 55 W – provides intense radiation action while maintaining specific flow parameters and water quality.
✅ Durability up to 16 000 hours – corresponds to about 666 days, or about 22 months of continuous work.
✅ Reduction of microorganisms up to 99,9% – effectiveness is achieved with proper flow, appropriate UV dose and proper water quality.
✅ An acid-resistant steel – the reaction chamber is resistant to corrosion and adapted to contact with water.
✅ Connection DN40 R1 1/2” – allows connection of the device to higher flow installations.
✅ Working pressure up to 10 bar – allows the lamp to be used in typical pressure installations.
✅ Vertical, horizontal or angled – makes it easy to adjust the position of the device to the available space.
✅ Simple replacement of the radiator – the service does not require unsealing of the hydraulic part of the device.
⭐ Application of TMA D10 sterilizer
✔ Single-family houses equipped with 2 to 3 bathrooms.
✔ Small holiday homes and apartments using their own or local water source.
✔ Offices and small commercial facilities where it is necessary to limit the presence of microorganisms in water.
✔ Gastronomy and hospitality, as part of a properly designed water treatment system.
✔ Wells and own shots, after prior testing and application of the required pre-filtration.
✔ Water ponds and small reservoirs, where UV radiation helps to limit the growth of bacteria and algae found in flowing water.
✔ Small industrial installations whose flow requirements correspond to the parameters of the device.
⭐ Disinfection of water with UV radiation
✔ The TMA D10 sterilizer uses UV C ultraviolet radiation with a wavelength of 254 nm.
✔ Water flowing through the chamber is exposed to radiation, which damages the genetic material of microorganisms and limits their possibility of further multiplication.
✔ With properly selected flow, UV dose and proper water parameters, the device can provide reduction of microorganisms up to 99,9%.
✔ The lamp helps neutralize, among others, Bacteria of the Coli group, Escherichia coli, fecal streptococci, Legionella and Clostridium perfringens.
✔ The disinfection process takes place without changing the taste and smell of water and without leaving chemical by-products in it.
✔ UV sterilization does not remove deposits, metals, chemical compounds or mechanical impurities, therefore the device should work with a properly selected filtration system.
⭐ Installation in water system
✔ The device can be mounted in vertical, horizontal or angle position, depending on the installation layout and manufacturer’s recommendations.
✔ The included handles allow stable attachment of the lamp in the prepared place.
✔ Connection DN40 R1 1/2” allows you to connect the device to the water system of the appropriate diameter.
✔ The design allows replacement of the radiator without opening the water chamber, which reduces the risk of unsealing the system during servicing.
✔ At the installation site, leave adequate space to remove the radiator and quartz cover.
✔ The sterilizer requires access to the 230 V electrical system.
✔ The maximum temperature of water entering the device is 45°C.
✔ Regular cleaning of the quartz shield helps to reduce limescale build-up and maintain effective UV penetration.
⭐ Technical specification
✔ Nominal flow rate: 3,90 m³/h at T10=95% transmission and 400 J/m² dose.
✔ Operating pressure: up to 10 bar (1,0 MPa).
✔ Connection: DN40 (R1 1/2”)
✔ UV radiator: 1 x 55 W, durability up to 16 000 hours.
✔ Body material: acid-resistant steel, satin finish (Ra< 0,8 µm).
✔ Dimensions: length 1 100 mm, diameter 70 mm.
✔ Weight with control system: 5,0 kg.
⭐ FAQ – Frequently Asked Questions
❓ Can TMA D10 disinfect water throughout your home?
✅ Yes, the device can be mounted on the main wiring of the installation and disinfect the water supplied to the whole house, provided that the flow does not exceed the capabilities of the lamp.
❓ What microorganisms neutralize the TMA D10 sterilizer?
✅ The lamp helps neutralize Bacteria of the Coli group, Escherichia coli, fecal streptococcus, Legionella, Clostridium perfringens and other bacteria and viruses present in the water.
❓ How long does UV heater last?
✅ The manufacturer declares the durability of the radiator at the level of 16 000 hours, which corresponds to about 666 days, i.e. about 22 months of continuous operation.
❓ Does replacing the radiator require draining water?
✅ The design allows you to replace the radiator itself without unsealing the water chamber. However, removing the quartz cover requires closing the inflow and proper protection of the installation.
❓ Does the lamp remove limescale, sand and rust?
✅ No, UV sterilizer does not remove mechanical impurities or chemical compounds. Before the device, use properly selected mechanical filters and treatment devices.
❓ Can TMA D10 be used for well water?
✅ Yes, but before installation, microbiological and physicochemical tests of water should be performed and filtration adapted to the detected impurities should be applied.
❓ How often should I clean the quartz cover?
✅ The frequency of cleaning depends on the quality and hardness of the water. The shield should be regularly inspected and deposits removed from it, which may limit the penetration of UV radiation.
❓ Is the device suitable for pond?
✅ Yes, the lamp can be used in installations that support water ponds and small tanks, where it helps to limit the growth of bacteria and algae in the flowing water.
Specifications
| Group | Name | Value |
|---|---|---|
| Parametry | Condition | new |
| Parametry | Invoice | With VAT invoice |
| Parametry | Brand | TMA |
| Parametry | Kind | other |
| Parametry | Capacity | 0 l |
| Parametry | Manufacturer code | D10 304 |
| Parametry | EAN (GTIN) | 5907413390047 |
| Parametry | Model | D10 304 |