{"product_id":"gliukozes-matuoklis-accutrend-plus-cholesteroliui-trigliceridams-ir-pieno-rugsciai","title":"Gliukozės matuoklis Accutrend Plus, cholesteroliui, trigliceridams ir pieno rūgščiai","description":"\u003ch2\u003eTrumpai apie prekę\u003c\/h2\u003e\u003cp\u003ePrekė: Gliukozės matuoklis Accutrend Plus, cholesteroliui, trigliceridams ir pieno rūgščiai. Kategorija: Gliukozės matuokliai.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGamintojas:\u003c\/strong\u003e Accu-Chek\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModelis:\u003c\/strong\u003e accutrend plus\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAccutrend Plus glucose meter - glucose, cholesterol, triglycerides, lactic acid\u003c\/p\u003e\u003cp\u003eAccutrend® Plus\u003c\/p\u003e\u003cp\u003eOne portable camera - four parameters\u003c\/p\u003e\u003cp\u003eAccutrend Plus is an apparatus that performs quantitative determinations of glucose, cholesterol, triglycerides and lactic acid directly from capillary blood. Roche belts specially designed for this purpose are used to determine each of these parameters.\u003c\/p\u003e\u003cp\u003eAccutrend Plus – a quick and simple assessment of cardiovascular risk factors\u003c\/p\u003e\u003cp\u003eTotal cholesterol, triglycerides and glucose in the blood: the most important parameters for diagnosis and monitoring of cardiovascular diseases.\u003c\/p\u003e\u003cp\u003eLactic acid: a key parameter for assessing the degree of fatigue after exercise, rehabilitation and care in critical cases.\u003c\/p\u003e\u003cp\u003eAccutrend Plus is designed so that it can be used outside the laboratory - e.g. in the doctor's office or in the hospital. It can also be used to take measurements at home or while playing sports. Determinations are made of capillary blood, and the results are given immediately.\u003c\/p\u003e\u003cp\u003ePrinciple of operation\u003c\/p\u003e\u003cp\u003eThe Accutrend Plus measures the intensity of the reaction coating of the test strip using a reflection photometer and calculates the concentration of the parameter in the sample using a series-specific algorithm. The result is displayed in mg\/dl or mmol\/l (for lactic acid only in mmol\/l) and stored in the camera memory automatically with the date, time and additional information. The camera stores up to 100 results for each parameter.\u003c\/p\u003e\u003cp\u003eKey benefits\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eEasy to use: Conveniently label cholesterol, triglycerides, blood glucose, and lactic acid from capillary blood using Roche Diagnostics test strips. Test strips can be stored at room temperature.\u003c\/li\u003e\n\u003cli\u003eResults obtained in a short time:\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eCholesterol - 180 seconds\u003c\/p\u003e\u003cp\u003etriglycerides - 174 seconds\u003c\/p\u003e\u003cp\u003eglucose - 12 seconds\u003c\/p\u003e\u003cp\u003elactic acid - 60 seconds\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBuilt-in security: Coding strips for series identification and parameter recognition.\u003c\/li\u003e\n\u003cli\u003eUser-help storage of results to manage and monitor results. You can store up to 100 results along with the date, time and additional information for each parameter.\u003c\/li\u003e\n\u003cli\u003eAccurate results: High precision and accuracy across the entire measuring range for all parameters.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eUnique test strip technology\u003c\/p\u003e\u003cp\u003eAccutrend Plus uses specially designed test strips for glucose (Accutrend Glucose), cholesterol (Accutrend Cholesterol), triglycerides (Accutrend Triglycerides) and lactic acid determinations of exceptional quality. The test strips are made up of the following elements:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eyellow protective mesh soaked with surfactant (application field)\u003c\/li\u003e\n\u003cli\u003eglass fibre layer separating blood cells\u003c\/li\u003e\n\u003cli\u003ereaction coating in which a colour reaction takes place\u003c\/li\u003e\n\u003cli\u003ebarcode on the bottom that the camera reads to confirm the type of test strip, i.e. Compliance of the batch number on the test strip with the code stored in the camera.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eBuilt-in security\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eThanks to the built-in security features, Accutrend Plus performs safety checking procedures to prevent potential errors and malfunctions and ensure accurate results.\u003c\/li\u003e\n\u003cli\u003eThe Accutrend Plus allows you to apply blood to the test strip inserted into the camera or outside the camera, e.g. when performing multiple markings.\u003c\/li\u003e\n\u003cli\u003eCoding strips for identifying a series of test strips and recognizing parameters are used to calibrate the device, which ensures even greater safety and proper operation of the camera.\u003c\/li\u003e\n\u003cli\u003eAccutrend Control Chol (cholesterol), Accutrend Control GLU (glucose), Accutrend Control TG (triglycerides) and BM-Control Lactate (lactic acid) control solutions can be used to further check the functioning of the apparatus.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFast and accurate result in three steps\u003c\/p\u003e\u003cp\u003e1. Turning on the camera\u003c\/p\u003e\u003cp\u003eTurn on the camera and slide the test strip into the guide. The flashing arrow signals that the lid of the measuring chamber must be opened to apply blood.\u003c\/p\u003e\u003cp\u003e2. Blood application\u003c\/p\u003e\u003cp\u003eTake a drop of blood from your fingertip and apply it to the yellow application field within 15 seconds. Do not touch the application field with your finger. Blood can also be applied outside the camera. (follow the instructions in the Accutrend Plus manual)\u003c\/p\u003e\u003cp\u003e3. Measurement\u003c\/p\u003e\u003cp\u003eClose the cover of the measuring chamber and wait for the result. All further actions are performed automatically by the camera. When the reaction is complete, the result will appear on the display. Values outside the measuring range will be displayed as “Hi” (above the measuring range) or “Lo” (below the measuring range).\u003c\/p\u003e\u003cp\u003eTechnical data\u003c\/p\u003e\u003cp\u003eMeasuring temperature ranges\u003c\/p\u003e\u003cp\u003eDepending on the parameter:\u003c\/p\u003e\u003cp\u003eCholesterol and triglycerides: 18-30 °C Glucose: 18-32 °C\u003c\/p\u003e\u003cp\u003eLactic acid: 15-35 °C\u003c\/p\u003e\u003cp\u003eMeasuring ranges\u003c\/p\u003e\u003cp\u003eBlood glucose: 20 - 600 mg\/dL (1,1 – 33,3 mmol\/L)\u003c\/p\u003e\u003cp\u003eCholesterol: 150 - 300 mg\/dL (3,88 – 7,76 mmol\/L)\u003c\/p\u003e\u003cp\u003eTriglycerides: 70 – 600 mg\/dL (0,80 – 6,86 mmol\/L)\u003c\/p\u003e\u003cp\u003eLactic acid: 0,8 – 21,7 mmol\/l (whole blood), 0,7 – 26 mmol\/l (plasma)\u003c\/p\u003e\u003cp\u003eTemperature range\u003c\/p\u003e\u003cp\u003e-25 °C - +70 °C\u003c\/p\u003e\u003cp\u003eRelative humidity\u003c\/p\u003e\u003cp\u003e10 – 85% (without condensation)\u003c\/p\u003e\u003cp\u003eMaterial for testing\u003c\/p\u003e\u003cp\u003eOne drop of fresh capillary blood *\u003c\/p\u003e\u003cp\u003eMemory capacity\u003c\/p\u003e\u003cp\u003e100 results; possible recording with date, time and additional information for each parameter\u003c\/p\u003e\u003cp\u003eTest principle\u003c\/p\u003e\u003cp\u003eReflection photometry\u003c\/p\u003e\u003cp\u003eDimensions\u003c\/p\u003e\u003cp\u003e154 x 81 x 30 mm\u003c\/p\u003e\u003cp\u003eWeight\u003c\/p\u003e\u003cp\u003e140 g without batteries\u003c\/p\u003e\u003cp\u003eAutomatic shutdown\u003c\/p\u003e\u003cp\u003eAfter 2 minutes if no button is pressed\u003c\/p\u003e\u003cp\u003ePower Requirements\u003c\/p\u003e\u003cp\u003e4 AAA 1,5 V alkaline batteries are enough to take more than 1000 measurements (new batteries)\u003c\/p\u003e\u003cp\u003eIsolation\u003c\/p\u003e\u003cp\u003eClass III\u003c\/p\u003e\u003cp\u003e* Detailed information is provided in the product leaflet.\u003c\/p\u003e\u003cp\u003eAccutrend® Plus\u003c\/p\u003e\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\u003cp\u003e1. Are the results reported by Accutrend Plus reliable?\u003c\/p\u003e\u003cp\u003e2. Does using Accutrend Plus require special training?\u003c\/p\u003e\u003cp\u003e3. Is Accutrend Plus useful for patients coming to see a doctor?\u003c\/p\u003e\u003cp\u003e4. Why should lactic acid concentration be measured using a portable apparatus when performing physical exercise?\u003c\/p\u003e\u003cp\u003e1. Are the results reported by Accutrend Plus reliable?\u003c\/p\u003e\u003cp\u003eThe results given by the camera are reliable for many reasons. The first is to use high quality test strips. In addition, studies have shown that the results reported by the apparatus are comparable to those obtained using recognised laboratory methods throughout the measurement range. What’s more, the security built into the camera additionally supports the proper functioning of the Accutrend Plus camera.\u003c\/p\u003e\u003cp\u003e2. Does using Accutrend Plus require special training?\u003c\/p\u003e\u003cp\u003eThe Accutrend Plus is very easy to use. To take the measurement, simply turn on the camera, insert the test strip, apply a drop of blood and close the cover of the measuring chamber. The camera can be used by a person who is a specialist in the field of medicine, as well as a person performing measurements on their own. No specific training is necessary to use the apparatus (the apparatus meets the safety requirements of DIN EN 61010-1 and the requirements of the EU Directive on in vitro diagnostic medical equipment 98\/79\/EG).\u003c\/p\u003e\u003cp\u003e3. Is Accutrend Plus useful for patients coming to see a doctor?\u003c\/p\u003e\u003cp\u003eMany patients treated in primary care centers have dyslipidaemia, metabolic syndrome, or diabetes. Diagnostic tests performed in such centers can significantly improve the diagnosis and treatment of patients with elevated levels of lipids or glucose in the blood. Accutrend Plus gives the results immediately, which allows you to discuss the risk profile of cardiovascular disease and treatment with the patient during the same visit. Your doctor may also take your Accutrend Plus with you on home visits.\u003c\/p\u003e\u003cp\u003e4. Why should lactic acid concentration be measured using a portable apparatus when performing physical exercise?\u003c\/p\u003e\u003cp\u003eDetermination of lactic acid in the blood allows you to control the intensity of exercise and adjust it to the values obtained. Thanks to this, you can reduce the risk of fatigue and injuries – not only in competitive sports, but also in recreational exercises.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eGroup\u003c\/th\u003e\n\u003cth\u003eName\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003enew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eInvoice\u003c\/td\u003e\n\u003ctd\u003eWithout VAT invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eMedical device\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eMedical device type\u003c\/td\u003e\n\u003ctd\u003eaccessories for a medical device or a product without an intended medical purpose\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eManufacturer of a medical device\u003c\/td\u003e\n\u003ctd\u003eRoche\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAccu-Chek\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eaccutrend plus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eBlood sample volume\u003c\/td\u003e\n\u003ctd\u003e0.7 μl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eMeasurement time\u003c\/td\u003e\n\u003ctd\u003e7 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eAverage measurement\u003c\/td\u003e\n\u003ctd\u003efrom 14 days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eNumber of memorized measurements\u003c\/td\u003e\n\u003ctd\u003e450\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eNumber of strips\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eNumber of lancets\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eAdditional features\u003c\/td\u003e\n\u003ctd\u003eaudible alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eSet components\u003c\/td\u003e\n\u003ctd\u003ebatteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003ebatteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eEAN (GTIN)\u003c\/td\u003e\n\u003ctd\u003e4015630936748\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eMeasurement\u003c\/td\u003e\n\u003ctd\u003echolesterol,glucose\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"DrogeriaMarzenie","offers":[{"title":"Default Title","offer_id":46104849023036,"sku":"14099002221","price":241.87,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0618\/2161\/6188\/files\/Accutrend-Plus-glucose-meter-chole-trig-ml-acid.jpg?v=1788014378","url":"https:\/\/market365.lt\/de\/products\/gliukozes-matuoklis-accutrend-plus-cholesteroliui-trigliceridams-ir-pieno-rugsciai","provider":"Market365","version":"1.0","type":"link"}