{"product_id":"gliukozes-jutiklis-sibionics-gs1-nuolatinio-gliukozes-stebejimo-sistema","title":"Gliukozės jutiklis SIBIONICS GS1, nuolatinio gliukozės stebėjimo sistema","description":"\u003ch2\u003eTrumpai apie prekę\u003c\/h2\u003e\u003cp\u003ePrekė: Gliukozės jutiklis SIBIONICS GS1, nuolatinio gliukozės stebėjimo sistema. Kategorija: Gliukozės matuokliai.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGamintojas:\u003c\/strong\u003e Sibionics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModelis:\u003c\/strong\u003e Sibionics GS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eThe Sibionics GS1 \u003c\/b\u003e continuous glucose monitoring system is intended for use in patients with type 1 and type 2 diabetes from 3 years of age. It is used for continuous monitoring of glucose concentration in intratissue fluid in real time, for single use. The Sibionics GS1 system can replace glucose measurement by taking a blood sample from the fingertip to make decisions about the treatment of diabetes, including insulin dosage.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eThe GS1 CGM system has clinically proven accuracy\u003c\/b\u003e\u003cb\u003e \u003c\/b\u003ei enables therapeutic decisions to be made based on sensor readings, including insulin dosing*.\u003c\/p\u003e\u003cp\u003e*Outside of situations: no value and\/or no trend arrow in the application and when glucose readings in the Sibionics GS1 system are incorrect or do not correspond to well-being. Glucose glucose meter testing should be performed. Do not ignore symptoms that may be caused by low and\/or high glucose levels.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eWhy Sibionics GS1?\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e14-day continuous glucose monitoring system\u003c\/li\u003e\n\u003cli\u003eReal-time glucose measurement\u003c\/li\u003e\n\u003cli\u003eSensor and transmitter in one device\u003c\/li\u003e\n\u003cli\u003eConfigurable alarms\u003c\/li\u003e\n\u003cli\u003eWHINING 8,83%\u003c\/li\u003e\n\u003cli\u003eWaterproof*\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*IP28 protection class. Protection against penetration of large objects with a diameter of not less than 12.5 mm and the effects of continuous immersion in water over 1 hour\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eThe package contains:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 sensor applicator\u003c\/li\u003e\n\u003cli\u003e1 sensor\u003c\/li\u003e\n\u003cli\u003e1 safety patch\u003c\/li\u003e\n\u003cli\u003e1 instructions for use\u003c\/li\u003e\n\u003cli\u003e1 abbreviated instructions for use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eSystem application locations:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe sensor can be placed on the back of the arm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eBy purchasing the CGM Sibionics GS1 sensor in this offer, you will receive an additional protective patch.\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eWith the Sibionics GS1 system, get:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePossibility of observing trends\u003c\/li\u003e\n\u003cli\u003eno need for puncture, scanning and calibration\u003c\/li\u003e\n\u003cli\u003ealarm with a very low glycemic level of 55 mg \/ dL (you will receive even when you have muted sounds on your phone)\u003c\/li\u003e\n\u003cli\u003eImproving quality of life by increasing awareness of hypoglycemia*.\u003c\/li\u003e\n\u003cli\u003eImproved glycaemic control (by reducing HbA1c) in children and adolescents*.\u003c\/li\u003e\n\u003cli\u003eThe SIBIONICS GS1 CGM system replaces glucose measurement by taking a blood sample from the fingertip to make decisions about the treatment of diabetes, including insulin dosage **\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e*Instructions for using the Sibionics GS1 system\u003c\/p\u003e\u003cp\u003e\u003cb\u003eThe Sibionics Pro View\u003c\/b\u003e web system\u003c\/p\u003e\u003cp\u003e\u003cb\u003e- \u003c\/b\u003eEasy and quick sharing of data with your doctor:\u003c\/p\u003e\u003col\u003e\n\u003cli\u003eThe doctor has the opportunity to observe the patient's glycemia in real time\u003c\/li\u003e\n\u003cli\u003eEasy way to link accounts\u003c\/li\u003e\n\u003cli\u003eAccess to rich data analytics, including m.in.:\u003c\/li\u003e\n\u003c\/ol\u003e\u003cul\u003e\n\u003cli\u003eAGP report\u003c\/li\u003e\n\u003cli\u003eGlucose Management Index (GMI)\u003c\/li\u003e\n\u003cli\u003eTIR, TAR and TBR parameters in terms of time and percentage\u003c\/li\u003e\n\u003cli\u003eGlucose variability index (CV)\u003c\/li\u003e\n\u003cli\u003eMean glucose\u003c\/li\u003e\n\u003cli\u003eSensor activity time\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eThe Sibionics mobile application works with Apple's Android and iOS operating systems.\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eWith the Sibionics GS1 system, get:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePossibility of observing trends\u003c\/li\u003e\n\u003cli\u003eno need for puncture, scanning and calibration\u003c\/li\u003e\n\u003cli\u003ealarm with a very low glycemic level of 55 mg \/ dL (you will receive even when you have muted sounds on your phone)\u003c\/li\u003e\n\u003cli\u003eImproving quality of life by increasing awareness of hypoglycemia*.\u003c\/li\u003e\n\u003cli\u003eImproved glycaemic control (by reducing HbA1c) in children and adolescents*.\u003c\/li\u003e\n\u003cli\u003eThe SIBIONICS GS1 CGM system replaces glucose measurement by taking a blood sample from the fingertip to make decisions about the treatment of diabetes, including insulin dosage **\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*Instructions for using the Sibionics GS1 system\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eThe Sibionics Pro View\u003c\/b\u003e web system\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e- \u003c\/b\u003eEasy and quick sharing of data with your doctor:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eThe doctor has the opportunity to observe the patient's glycemia in real time\u003c\/li\u003e\n\u003cli\u003eEasy way to link accounts\u003c\/li\u003e\n\u003cli\u003eAccess to rich data analytics, including m.in.:\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cul\u003e\n\u003cli\u003eAGP report\u003c\/li\u003e\n\u003cli\u003eGlucose Management Index (GMI)\u003c\/li\u003e\n\u003cli\u003eTIR, TAR and TBR parameters in terms of time and percentage\u003c\/li\u003e\n\u003cli\u003eGlucose variability index (CV)\u003c\/li\u003e\n\u003cli\u003eMean glucose\u003c\/li\u003e\n\u003cli\u003eSensor activity time\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eThe Sibionics mobile application works with Apple's Android and iOS operating systems.\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003ePurpose of medical device:\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eThe Sibionics GS1 continuous glucose monitoring system is intended for use in patients with type 1 and type 2 diabetes from 3 years of age. It is used for continuous monitoring of glucose concentration in intratissue fluid in real time, for single use. The Sibionics GS1 system can replace glucose measurement by taking a blood sample from the fingertip to make decisions about the treatment of diabetes, including insulin dosage.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eManufacturer: \u003c\/b\u003eShenzhen SiSensing Co., Ltd.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eResponsible person (EC-REP): \u003c\/b\u003eShanghai International Holding Corp. GmbH (Europe)\u003c\/p\u003e\u003cp\u003e\u003cb\u003eImporter and advertiser: \u003c\/b\u003eDiagnosis S.A. ul. Andersa 38A, 15-113 Białystok, Poland.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eThis is a medical device.\u003c\/b\u003e \u003cb\u003eUse it according to the instructions for use or label.\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eWarnings and safety information:\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eBefore using the SIBIONICS GS1 App for your smartphone (hereinafter referred to as the smartphone app), the SIBIONICS GSW App for your smartwatch (hereinafter referred to as the smartwatch app), and the SIBIONICS GS1 glucose monitoring system (hereinafter referred to as the GS1 CGM system), read all instructions and leaflet. Smartwach is a separate product that can be purchased in selected countries. The instructions for use shall contain all safety information and instructions for use. Consult your doctor about how to use information from the system to help manage diabetes.\u003c\/p\u003e\u003cp\u003eFailure to follow the instructions for use of the GS1 CGM system may lead to overlooking very low or very high glucose levels and making a therapeutic decision inadequate to the patient’s health. If the results obtained with the system do not correspond to the symptoms and\/or expected values, measure the glucose concentration with a glucose meter by pricking the fingertip and on this basis make a decision on treatment.\u003c\/p\u003e\u003cp\u003eIf necessary, consult a doctor.\u003c\/p\u003e\u003cp\u003eThe system can replace a blood glucose test, except in the following situations. These are situations when we perform a blood glucose test in order to make decisions related to the treatment of diabetes – then the readings from the sensor may not accurately reflect the actual blood glucose concentration:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eNo value and\/or no arrow\u003c\/li\u003e\n\u003cli\u003eDo a blood glucose test if you think your sensor glucose readings are abnormal or do not match your well-being. Do not ignore symptoms that may be caused by low and\/or high glucose levels.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eUsing the GS1 CGM system in such situations can lead to wrong decisions regarding the treatment of diabetes. Read the chapter “13. Treatment decisions” in this document.\u003c\/p\u003e\u003cp\u003eFor more information on how to make treatment decisions with the GS1 CGM system, please refer to the sections “1.4 Safety Instructions”, “13. Treatment decisions” and “6. Glucose alarms.”\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eGroup\u003c\/th\u003e\n\u003cth\u003eName\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003enew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eInvoice\u003c\/td\u003e\n\u003ctd\u003eWith VAT invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eMedical device\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eMedical device type\u003c\/td\u003e\n\u003ctd\u003emedical device or in-vitro diagnostic medical device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eManufacturer of a medical device\u003c\/td\u003e\n\u003ctd\u003eShenzhen SiSensing Co., Ltd.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eAuthorized representative\u003c\/td\u003e\n\u003ctd\u003eShanghai International Holding Corp. GmbH (Europe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eMeasurement\u003c\/td\u003e\n\u003ctd\u003eglucose\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSibionics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eManufacturer code\u003c\/td\u003e\n\u003ctd\u003eCGM000001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSibionics GS1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eAverage measurement\u003c\/td\u003e\n\u003ctd\u003efrom 14 days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eProduct width\u003c\/td\u003e\n\u003ctd\u003e33.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eProduct height\u003c\/td\u003e\n\u003ctd\u003e20 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eProduct depth\u003c\/td\u003e\n\u003ctd\u003e5.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eEAN (GTIN)\u003c\/td\u003e\n\u003ctd\u003e6972831642008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003ePackaging status\u003c\/td\u003e\n\u003ctd\u003eoriginal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eBatteries included\u003c\/td\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eCertificates of conformity\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Diagnosis_pl","offers":[{"title":"Default Title","offer_id":46104718278716,"sku":"17422271683","price":85.41,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0618\/2161\/6188\/files\/SENSOR-CGM-SIBIONICS-GS1-CONTINUOUS-GLUCOSE-MONITORING-SYSTEM.jpg?v=1788012319","url":"https:\/\/market365.lt\/de\/products\/gliukozes-jutiklis-sibionics-gs1-nuolatinio-gliukozes-stebejimo-sistema","provider":"Market365","version":"1.0","type":"link"}